Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Apply Date:
12/17/2023
Applicant:
Stephanie Bebee
Description:
SFR CVPLAN2.5 T22-M0062 V2 Structural changes

Permit Reviews

Permit Number - TC-MDP-0923-01534
Permit Status: Complete
Permit Description: SFR CVPLAN2.5 T22-M0062 V2 Structural changes
Start Date Submittal Complete Date Status  
12/18/2023 SITE FROM MODEL PERMIT - PRODUCTION v.1 12/26/2023 APPROVED Review Details
07/16/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 07/17/2024 APPROVED Review Details
02/27/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 03/04/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0923-01534
Permit Status: Complete
Permit Description: SFR CVPLAN2.5 T22-M0062 V2 Structural changes
Date Description Comments
12/18/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
09/14/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/17/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
07/17/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-0923-01534
Permite Description: SFR CVPLAN2.5 T22-M0062 V2 Structural changes
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
07/11/2024 RSBU - Building Final N/A Re-inspection required 7/11/24; all exterior pvc needs to be painted or coated for protection from UV

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0923-01534
Permit Description: SFR CVPLAN2.5 T22-M0062 V2 Structural changes
Total Completed Inspections - 22
Date Description Inspector Results Comments
01/12/2024 COT - RSPL - Sewer Passed Sewer line is connected to underground plumbing and main sewer line. Underground plumbing is under water test without any leaks. Backwater valve is installed between clean outs. Okay to shade piping and backfill trenches.
01/12/2024 COT - RSPL - Rough Soil Passed Sewer line is connected to underground plumbing and main sewer line. Underground plumbing is under water test without any leaks. Backwater valve is installed between clean outs. Okay to shade piping and backfill trenches.
01/12/2024 COT - RSPL - Backwater Valve Passed Sewer line is connected to underground plumbing and main sewer line. Underground plumbing is under water test without any leaks. Backwater valve is installed between clean outs. Okay to shade piping and backfill trenches.
01/12/2024 COT - RSPL - Yard Water Line Passed Main Water line is connected to water meter and under line pressure. Okay to shade pipe and backfill trench.
01/17/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Ufer ground is in place, post tension cabling is installed and properly supported, rebar reinforcement is installed where required per plans, all plumbing pipes are properly protected with foam wrap or plastic boxes, and all shear wall clips are installed and properly supported. Okay to pour concrete slab and footings.
01/17/2024 COT - RSBU - Preslab Passed Ufer ground is in place, post tension cabling is installed and properly supported, rebar reinforcement is installed where required per plans, all plumbing pipes are properly protected with foam wrap or plastic boxes, and all shear wall clips are installed and properly supported. Okay to pour concrete slab and footings.
01/17/2024 COT - RSEL - Electrical Underground Passed Electrical underground for kitchen island is in place. Okay to pour concrete slab.
01/17/2024 COT - RSEL - Grounding/Bonding Passed Ufer ground is placed in footing. Okay to pour concrete.
02/09/2024 COT - RSBU - Exterior Clips/Sheathing Passed All exterior shear walls are properly installed and nailed off per plans. All shear wall clips and H2.5 clips are properly nailed off. Okay to dry-in exterior walls.
02/09/2024 COT - RSBU - Roof Nailing Passed Roof TJI-Trusses are properly installed and nailed off. Okay to proceed with roofing material installation.
03/04/2024 BULD - Electrical Clearance Passed 3/4/24: Address tag has been installed on front of panel. Okay to install meter and energize system.
03/19/2024 COT - RSPL - Gas Pressure Test Passed
03/27/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
05/02/2024 COT - RSBU - Interior Shear Bracing Passed
06/28/2024 COT - BULD - SWG Clearance Passed SWG for meter only
07/11/2024 RSBU - Building Progress Passed
07/11/2024 COT - RSPL - Plumbing Final Passed
07/11/2024 COT - RSME - Mechanical Final Passed
07/11/2024 COT - RSEL - Outdoor Lighting Passed
07/11/2024 COT - RSEL - Electrical Final Passed
07/12/2024 ENGR Engineering Final Passed It has been noted that the landing at the bottom of the steps for this unit is not ADA compliant. It exceeds more than 2% in the running slope.
07/15/2024 RSBU - Building Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
PT REPORT LOT 54 -2024-02-20_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CBT 54 PLOT PLAN FOR PERMIT_V1.PDF DOCUMENTS VIEW
CBT 54 PT CERT-2023-12-17_V1.PDF DOCUMENTS VIEW