Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
In Review
Type:
Model Building Permit
Address NEW:
6243 E CAMPOLINA TR
Apply Date:
08/26/2026
Applicant:
Helen Ormsby
Description:
Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)

Permit Reviews

Permit Number - TC-MDP-0826-00692
Permit Status: In review
Permit Description: Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
Start Date Submittal Complete Date Status  
09/04/2026 SITE FROM MODEL PERMIT - SUBDIVISION v.1 09/14/2026 REQUIRES RESUBMIT Review Details
09/17/2026 SITE FROM MODEL PERMIT - SUBDIVISION v.2 09/18/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0826-00692
Permit Status: In review
Permit Description: Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
Total Outstanding Activity Conditions - 4
Date Name
08/27/2026 Prior to Final - Required Documents - Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
08/27/2026 Prior to Final - Special Inspections - SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
09/14/2026 Prior to Final - Special Inspections - SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
09/14/2026 Prior to Final - Required Documents - Post-Installed Anchor Inspection Report is required.

Conditions

Permit Number - TC-MDP-0826-00692
Permit Status: In review
Permit Description: Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
Date Description Comments
08/27/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
08/27/2026 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: In Review
Permit Number: TC-MDP-0826-00692
Permite Description: Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
10/21/2026 COT - RSPL - Sewer N/A Canceled 10/21/2026
Canceled at contractor request.
10/21/2026 COT - RSPL - Yard Water Line N/A Canceled 10/21/2026
Canceled at contractor request.
10/21/2026 COT - RSPL - Rough Soil N/A Canceled 10/21/2026
Canceled at contractor request.
10/26/2026 COT - RSEL - Electrical Underground N/A Not Applicable
10/26/2026 COT - RSBU - Excavation/Rebar/Zoning N/A Re-inspection required 10-26-26 Support rebar at south west at both footers at both corners*cleanout trash and debris from footers*rebar for uffer is required a minimum of 24” overlap*repair all tears and rips at vapor barrier throughout. More items may be added. Reinspect is required
10/26/2026 COT - RSBU - Preslab N/A Re-inspection required 10-26-26 Support rebar at south west at both footers at both corners*cleanout trash and debris from footers*rebar for uffer is required a minimum of 24” overlap*repair all tears and rips at vapor barrier throughout. More items may be added. Reinspect is required
11/03/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 11/03/2026
Add anchor bolts at marked locations, missing double stud at wall and floor truss for girder truss continuous to foundation at marked locations, missing hangers and clips at stair landing, add nails to fasten LSTH8 at rear shear wall, add straps per detail at rear shear wall, add bolts to HTT5 at interior shearwall.
11/03/2026 COT - RSEL - Grounding/Bonding N/A Not Ready 11/03/2026
Not ready.

Completed Inspections

Permit Status: In Review
Permit Number: TC-MDP-0826-00692
Permit Description: Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
Total Completed Inspections - 11
Date Description Inspector Results Comments
10/23/2026 COT - RSPL - Sewer Passed 10-23-26 OK to proceed. Shading is required.
10/23/2026 COT - RSPL - Yard Water Line Passed 10-23-26 OK to proceed. Shading is required.
10/23/2026 COT - RSPL - Rough Soil Passed 10-23-26 OK to proceed
10/26/2026 BULD - Electrical Clearance Passed 10-26-26 ECO Clearance approved
10/27/2026 COT - RSBU - Excavation/Rebar/Zoning Passed 10-27-26 all previous corrections have been made OK to pour
10/27/2026 COT - RSBU - Preslab Passed 10-27-26 all previous corrections have been made OK to pour
11/03/2026 COT - RSBU - Roof Nailing Passed 11/03/2026
Approved per plan.
11/04/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 11/04/2026
All corrections made.
11/06/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 11/06/2026
Approved per plan. Added fire caulk at top penetrations. Added blocking to floor truss opening near garage.
11/06/2026 COT - RSPL - Gas Pressure Test Passed
11/06/2026 COT - RSEL - Grounding/Bonding Passed 11/06/2026
Tied into with main service with grounding rods.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
BHK 2 D1_V1.PDF DOCUMENTS VIEW
BHK 2 SIC-2026-09-15_V2.PDF DOCUMENTS VIEW