Permit: TC-MDP-0826-00692
Permit Details
Status:
In Review
Type:
Model Building Permit
Address:
6243 E CAMPOLINA TR
Address NEW:
6243 E CAMPOLINA TR
Apply Date:
08/26/2026
Applicant:
Helen Ormsby
Description:
Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
Permit Reviews
Permit Number - TC-MDP-0826-00692
Permit Status: In review
Permit Description: Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/04/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 09/14/2026 | REQUIRES RESUBMIT |
| 09/17/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.2 | 09/18/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0826-00692
Permit Status: In review
Permit Description: Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 08/27/2026 | Prior to Final - Required Documents - Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 08/27/2026 | Prior to Final - Special Inspections - SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 09/14/2026 | Prior to Final - Special Inspections - SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 09/14/2026 | Prior to Final - Required Documents - Post-Installed Anchor Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0826-00692
Permit Status: In review
Permit Description: Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
| Date | Description | Comments |
|---|---|---|
| 08/27/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 08/27/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: In Review
Permit Number: TC-MDP-0826-00692
Permite Description: Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
Total Outstanding Inspections - 8
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/21/2026 | COT - RSPL - Sewer | N/A | Canceled | 10/21/2026 Canceled at contractor request. |
| 10/21/2026 | COT - RSPL - Yard Water Line | N/A | Canceled | 10/21/2026 Canceled at contractor request. |
| 10/21/2026 | COT - RSPL - Rough Soil | N/A | Canceled | 10/21/2026 Canceled at contractor request. |
| 10/26/2026 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
| 10/26/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 10-26-26 Support rebar at south west at both footers at both corners*cleanout trash and debris from footers*rebar for uffer is required a minimum of 24” overlap*repair all tears and rips at vapor barrier throughout. More items may be added. Reinspect is required |
| 10/26/2026 | COT - RSBU - Preslab | N/A | Re-inspection required | 10-26-26 Support rebar at south west at both footers at both corners*cleanout trash and debris from footers*rebar for uffer is required a minimum of 24” overlap*repair all tears and rips at vapor barrier throughout. More items may be added. Reinspect is required |
| 11/03/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 11/03/2026 Add anchor bolts at marked locations, missing double stud at wall and floor truss for girder truss continuous to foundation at marked locations, missing hangers and clips at stair landing, add nails to fasten LSTH8 at rear shear wall, add straps per detail at rear shear wall, add bolts to HTT5 at interior shearwall. |
| 11/03/2026 | COT - RSEL - Grounding/Bonding | N/A | Not Ready | 11/03/2026 Not ready. |
Completed Inspections
Permit Status: In Review
Permit Number: TC-MDP-0826-00692
Permit Description: Blackhawk C30G Model Plan (Model Master Plan TC-MDP-0126-00036)
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/23/2026 | COT - RSPL - Sewer | Passed | 10-23-26 OK to proceed. Shading is required. | |
| 10/23/2026 | COT - RSPL - Yard Water Line | Passed | 10-23-26 OK to proceed. Shading is required. | |
| 10/23/2026 | COT - RSPL - Rough Soil | Passed | 10-23-26 OK to proceed | |
| 10/26/2026 | BULD - Electrical Clearance | Passed | 10-26-26 ECO Clearance approved | |
| 10/27/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 10-27-26 all previous corrections have been made OK to pour | |
| 10/27/2026 | COT - RSBU - Preslab | Passed | 10-27-26 all previous corrections have been made OK to pour | |
| 11/03/2026 | COT - RSBU - Roof Nailing | Passed | 11/03/2026 Approved per plan. |
|
| 11/04/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 11/04/2026 All corrections made. |
|
| 11/06/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 11/06/2026 Approved per plan. Added fire caulk at top penetrations. Added blocking to floor truss opening near garage. |
|
| 11/06/2026 | COT - RSPL - Gas Pressure Test | Passed | ||
| 11/06/2026 | COT - RSEL - Grounding/Bonding | Passed | 11/06/2026 Tied into with main service with grounding rods. |