Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Canceled | 11-2-26 Cancel per Super | |
| 11/03/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 11/03/2026 Add anchor bolts at marked locations, missing double stud at wall and floor truss for girder truss continuous to foundation at marked locations, missing hangers and clips at stair landing, add nails to fasten LSTH8 at rear shear wall, add straps per detail at rear shear wall, add bolts to HTT5 at interior shearwall. |
|
| 11/04/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 11/04/2026 All corrections made. |