Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0825-00488
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
9620 E MEOLA DR
Address NEW:
9620 E MEOLA DR
Apply Date:
11/20/2025
Applicant:
Celina Rodriguez
Description:
Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
Permit Reviews
Permit Number - TC-MDP-0825-00488
Permit Status: Inspections
Permit Description: Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/24/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 12/03/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0825-00488
Permit Status: Inspections
Permit Description: Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 08/28/2025 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 08/28/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
| 11/24/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 11/24/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 11/24/2025 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0825-00488
Permit Status: Inspections
Permit Description: Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
| Date | Description | Comments |
|---|---|---|
| 08/28/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 08/28/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0825-00488
Permite Description: Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/17/2025 | COT - RSEL - Electrical Underground | N/A | Partial Pass | Partial pass for user, will check connection at later date |
| 12/31/2025 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 12/31/2025 Engineer fix/letter required at rear patio column not poured correctly. Add anchor bolts at marked locations, add shot pins as marked 6" from sill plate edges on interior walls, add roof nails to panel at marked location on floor in great room, add washer plates to anchor bolts at SW11 in bedroom 3. Add anchor bolts on sill plate edges within 12" at SW9 inside garage - no washer plates required. Add 2x4 post on interior bearing wall to make 3-point bearing point for girder truss A8G. A2M trusses need bracing. |
| 12/31/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 12/31/2025 Engineer fix/letter required at rear patio column not poured correctly. Add anchor bolts at marked locations, add shot pins as marked 6" from sill plate edges on interior walls, add roof nails to panel at marked location on floor in great room, add washer plates to anchor bolts at SW11 in bedroom 3. Add anchor bolts on sill plate edges within 12" at SW9 inside garage - no washer plates required. Add 2x4 post on interior bearing wall to make 3-point bearing point for girder truss A8G. A2M trusses need bracing. |
| 01/21/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 01/21/2026 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0825-00488
Permit Description: Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2025 | COT - RSPL - Yard Water Line | Passed | 12.11.25 Approved |
|
| 12/11/2025 | COT - RSPL - Rough Soil | Passed | 12.11.25 Approved |
|
| 12/11/2025 | COT - RSPL - Sewer | Passed | 12.11.25 Approved |
|
| 12/17/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Passed 12/17/25 ok to pour concrete | |
| 12/17/2025 | COT - RSBU - Preslab | Passed | Passed 12/17/25 ok to pour concrete | |
| 12/17/2025 | COT - RSEL - Grounding/Bonding | Passed | Partial pass for user, will check connection at later date | |
| 01/06/2026 | COT - RSBU - Roof Nailing | Passed | 01/06/2026 Corrections made to prior 12/31/25 inspection. |
|
| 01/21/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 01/21/2026 Verified fix to rear porch column. |
|
| 01/21/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 01/21/2026 | BULD - Electrical Clearance | Passed |