Celina Rodriguez
Description:
Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)

Permit Reviews

Permit Number - TC-MDP-0825-00488
Permit Status: Inspections
Permit Description: Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
Start Date Submittal Complete Date Status  
11/24/2025 SITE FROM MODEL PERMIT - PRODUCTION v.1 12/03/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0825-00488
Permit Status: Inspections
Permit Description: Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
Total Outstanding Activity Conditions - 5
Date Name
08/28/2025 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
08/28/2025 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
11/24/2025 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
11/24/2025 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
11/24/2025 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.

Conditions

Permit Number - TC-MDP-0825-00488
Permit Status: Inspections
Permit Description: Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
Date Description Comments
08/28/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
08/28/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0825-00488
Permite Description: Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
12/17/2025 COT - RSEL - Electrical Underground N/A Partial Pass Partial pass for user, will check connection at later date
12/31/2025 COT - RSBU - Roof Nailing N/A Re-inspection required 12/31/2025
Engineer fix/letter required at rear patio column not poured correctly. Add anchor bolts at marked locations, add shot pins as marked 6" from sill plate edges on interior walls, add roof nails to panel at marked location on floor in great room, add washer plates to anchor bolts at SW11 in bedroom 3. Add anchor bolts on sill plate edges within 12" at SW9 inside garage - no washer plates required. Add 2x4 post on interior bearing wall to make 3-point bearing point for girder truss A8G. A2M trusses need bracing.
12/31/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 12/31/2025
Engineer fix/letter required at rear patio column not poured correctly. Add anchor bolts at marked locations, add shot pins as marked 6" from sill plate edges on interior walls, add roof nails to panel at marked location on floor in great room, add washer plates to anchor bolts at SW11 in bedroom 3. Add anchor bolts on sill plate edges within 12" at SW9 inside garage - no washer plates required. Add 2x4 post on interior bearing wall to make 3-point bearing point for girder truss A8G. A2M trusses need bracing.
01/21/2026 COT - BULD - SWG Clearance N/A Not Applicable
01/21/2026 COT - RSPL - Gas Pressure Test N/A Not Applicable

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0825-00488
Permit Description: Mirador Point 1584 Plan (Model master plan TC-MDP-0125-00031)
Total Completed Inspections - 10
Date Description Inspector Results Comments
12/11/2025 COT - RSPL - Yard Water Line Passed 12.11.25
Approved
12/11/2025 COT - RSPL - Rough Soil Passed 12.11.25
Approved
12/11/2025 COT - RSPL - Sewer Passed 12.11.25
Approved
12/17/2025 COT - RSBU - Excavation/Rebar/Zoning Passed Passed 12/17/25 ok to pour concrete
12/17/2025 COT - RSBU - Preslab Passed Passed 12/17/25 ok to pour concrete
12/17/2025 COT - RSEL - Grounding/Bonding Passed Partial pass for user, will check connection at later date
01/06/2026 COT - RSBU - Roof Nailing Passed 01/06/2026
Corrections made to prior 12/31/25 inspection.
01/21/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 01/21/2026
Verified fix to rear porch column.
01/21/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
01/21/2026 BULD - Electrical Clearance Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
MIRADOR POINT - LOT 135 START_V1.PDF DOCUMENTS VIEW
MP 135 SIC-2025-11-20_V1.PDF DOCUMENTS VIEW