Permit: TC-MDP-0823-01452
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
12774 E MEAGAN RIDGE PL
Address NEW:
12774 E MEAGAN RIDGE PL
Apply Date:
04/22/2024
Applicant:
Description:
SFR RKM45R T21-M0093 (REVISION Delta 4)
Permit Reviews
Permit Number - TC-MDP-0823-01452
Permit Status: Inspections complete
Permit Description: SFR RKM45R T21-M0093 (REVISION Delta 4)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/26/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 05/01/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0823-01452
Permit Status: Inspections complete
Permit Description: SFR RKM45R T21-M0093 (REVISION Delta 4)
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 04/30/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 04/30/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 04/30/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 04/30/2024 | Post-Tension Inspection Report is required. |
| 04/30/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0823-01452
Permit Status: Inspections complete
Permit Description: SFR RKM45R T21-M0093 (REVISION Delta 4)
| Date | Description | Comments |
|---|---|---|
| 08/23/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 04/30/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0823-01452
Permit Description: SFR RKM45R T21-M0093 (REVISION Delta 4)
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/05/2024 | COT - RSPL - Rough Soil | Passed | Underground plumbing is properly connected to sewer line, green tracer wire is installed from clean outs to sewer connection, entire system is under a 10' water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 06/05/2024 | COT - RSPL - Sewer | Passed | Underground plumbing is properly connected to sewer line, green tracer wire is installed from clean outs to sewer connection, entire system is under a 10' water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 06/05/2024 | COT - RSPL - Yard Water Line | Passed | Main water supply line is connected to meter and under street pressure with no leaks. Blue tracer wire is installed on pipe from meter to house inlet. Okay to shade pipe and backfill trench. | |
| 06/24/2024 | COT - RSEL - Electrical Underground | Passed | ||
| 06/24/2024 | COT - RSBU - Preslab | Passed | ||
| 06/24/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 06/24/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 07/24/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Bottom plate is properly secured to concrete floor with titanium bolts, red heads, cut nails, shot pins, or masa clips. Shear wall clips and hold downs are properly nailed to studs and bolted to concrete floor through bottom plate. Plywood sheathing for shear walls are properly secured to studs per plan requirements. Okay to proceed with mechanical, electrical, and plumbing rough-in. | |
| 07/24/2024 | COT - RSBU - Roof Nailing | Passed | Roof trusses are properly secured to top plate with nails and H2.5 clips. All bracing and rat runs are installed. Plywood sheathing for roof deck is properly nailed to trusses. Okay to proceed with mechanical, electrical, and plumbing rough-in. | |
| 08/23/2024 | BULD - Electrical Clearance | Passed | Okay to energize panel. ECO Clearance issued to TEP for 12774 E Meagan Ridge Place. | |
| 08/26/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 08/26/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
| 09/13/2024 | COT - RSBU - Interior Shear Bracing | Passed | Drywall is properly secured to studs per plan requirements of the drywall shear walls. Okay to proceed with tape, texture, and paint | |
| 10/23/2024 | COT - BULD - SWG Clearance | Passed | Gas valves are installed in kitchen, laundry, attic, and garage for all gas appliances. Okay to proceed with gas meter installation and turn on. SWG Clearance issued. | |
| 11/20/2024 | COT - RSEL - Electrical Final | Passed | 11-20-24, building ,mechanical, electrical, outdoor lighting, plumbing finals are all approved. | |
| 11/20/2024 | COT - RSEL - Outdoor Lighting | Passed | 11-20-24, building ,mechanical, electrical, outdoor lighting, plumbing finals are all approved. | |
| 11/20/2024 | COT - RSME - Mechanical Final | Passed | 11-20-24, building ,mechanical, electrical, outdoor lighting, plumbing finals are all approved. | |
| 11/20/2024 | COT - RSPL - Plumbing Final | Passed | 11-20-24, building ,mechanical, electrical, outdoor lighting, plumbing finals are all approved. | |
| 11/20/2024 | ENGR Engineering Final | Passed | CO Ready | |
| 11/20/2024 | RSBU - Building Final | Passed | 11-20-24, building ,mechanical, electrical, outdoor lighting, plumbing finals are all approved. | |
| 11/20/2024 | RSBU - Building Progress | Passed | 11-20-24, building ,mechanical, electrical, outdoor lighting, plumbing finals are all approved. |