Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Apply Date:
05/28/2024
Applicant:
Description:
SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes

Permit Reviews

Permit Number - TC-MDP-0823-01344
Permit Status: Inspections complete
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes
Start Date Submittal Complete Date Status  
05/30/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 06/04/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0823-01344
Permit Status: Inspections complete
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes
Total Outstanding Activity Conditions - 5
Date Name
06/04/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
06/04/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
06/04/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
06/04/2024 Post-Tension Inspection Report is required.
06/04/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.

Conditions

Permit Number - TC-MDP-0823-01344
Permit Status: Inspections complete
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes
Date Description Comments
08/08/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
06/04/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0823-01344
Permite Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
07/15/2024 COT - RSBU - Excavation/Rebar/Zoning N/A Re-inspection required 7/15/24: rebar not to schedule at front perimeter of bedroom 4
07/15/2024 COT - RSBU - Preslab N/A Re-inspection required 7/15/24: rebar not to schedule at front perimeter of bedroom 4
09/18/2024 RSBU - Building Progress N/A Canceled

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0823-01344
Permit Description: SFR RKF55J T21-M0088 REVISION-Grade & Structural Changes
Total Completed Inspections - 22
Date Description Inspector Results Comments
07/03/2024 COT - RSPL - Backwater Valve Passed Underground plumbing is connected to main sewer line with backwater valve installed between clean outs. Complete system is under water test with no leaks.
07/03/2024 COT - RSPL - Rough Soil Passed Underground plumbing is connected to main sewer line with backwater valve installed between clean outs. Complete system is under water test with no leaks.
07/03/2024 COT - RSPL - Sewer Passed Underground plumbing is connected to main sewer line with backwater valve installed between clean outs. Complete system is under water test with no leaks.
07/03/2024 COT - RSPL - Yard Water Line Passed Main water supply line is connected to City Water with a meter and is under street pressure with no leaks. Okay to shade pipe and backfill trench.
07/15/2024 COT - RSEL - Grounding/Bonding Passed
07/15/2024 COT - RSEL - Electrical Underground Passed
07/16/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
07/16/2024 COT - RSBU - Preslab Passed
08/20/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 8/20/2024 corrections were made.
08/20/2024 COT - RSBU - Roof Nailing Passed
10/03/2024 COT - RSPL - Gas Pressure Test Passed
10/07/2024 BULD - Electrical Clearance Passed 10/7/24: All 25 circuits are roughed in to electrical panel. ECO Clearance issued
10/07/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 10/7/24: All items from previous inspection have been corrected. Okay to proceed with installation of insulation and drywall.
10/25/2024 COT - RSBU - Interior Shear Bracing Passed 10-25-24, interior shear bracing inspection approved. Okay to tape and texture.
12/18/2024 COT - BULD - SWG Clearance Passed 12/18/24 CLEARANCE for SWG approved.
01/09/2025 COT - RSEL - Electrical Final Passed Passed final 1/9/25 clearance ECO
01/09/2025 COT - RSME - Mechanical Final Passed Passed final 1/9/25
01/10/2025 RSBU - Building Final Passed Passed final 1/10/25
01/09/2025 RSBU - Building Progress Passed Passed final 1/9/25
01/09/2025 COT - RSEL - Outdoor Lighting Passed Passed final 1/9/25
01/10/2025 COT - RSPL - Plumbing Final Passed Passed final 1/10/25
02/13/2025 ENGR Engineering Final Passed CO Ready

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
1_SITEPLAN_V1.PDF DOCUMENTS VIEW
1_SPECIAL INSPECTION CERT-2024-05-28_V1.PDF DOCUMENTS VIEW