Permit: TC-MDP-0725-00379
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
6117 E CAMPOLINA TR
Address NEW:
6117 E CAMPOLINA TR
Apply Date:
07/09/2025
Applicant:
Cindy Nemo
Description:
Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493)
Permit Reviews
Permit Number - TC-MDP-0725-00379
Permit Status: Inspections
Permit Description: Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/09/2025 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 07/09/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0725-00379
Permit Status: Inspections
Permit Description: Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493)
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 07/02/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 07/02/2025 | Post-Tension Inspection Report is required. |
| 07/02/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
| 07/09/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0725-00379
Permit Status: Inspections
Permit Description: Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493)
| Date | Description | Comments |
|---|---|---|
| 07/09/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 07/02/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0725-00379
Permite Description: Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493)
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2026 | COT - RSEL - Grounding/Bonding | N/A | Partial Pass | 05/08/2026 Ufer only. |
| 07/27/2026 | COT - RSEL - Electrical Final | N/A | Not Ready | Coat all exterior plastic pipes. Threshold at garage shall be ADA standard. Hot water heater pipe shall be insulated with R3 insulation. Running water at primary bathroom lav. Provide refrigerant caps at condenser unit. Ensure unit is leveled. T stat shall be at 48”. AAV at kitchen requires aces panel. 7/27/2026AAV at kitchen requires access panel. Front Door handle not properly installed. 7/27/2026 |
| 07/27/2026 | COT - RSME - Mechanical Final | N/A | Not Ready | Coat all exterior plastic pipes. Threshold at garage shall be ADA standard. Hot water heater pipe shall be insulated with R3 insulation. Running water at primary bathroom lav. Provide refrigerant caps at condenser unit. Ensure unit is leveled. T stat shall be at 48”. AAV at kitchen requires aces panel. 7/27/2026AAV at kitchen requires access panel. Front Door handle not properly installed. 7/27/2026 |
| 07/27/2026 | COT - RSPL - Plumbing Final | N/A | Not Ready | Coat all exterior plastic pipes. Threshold at garage shall be ADA standard. Hot water heater pipe shall be insulated with R3 insulation. Running water at primary bathroom lav. Provide refrigerant caps at condenser unit. Ensure unit is leveled. T stat shall be at 48”. AAV at kitchen requires aces panel. 7/27/2026AAV at kitchen requires access panel. Front Door handle not properly installed. 7/27/2026 |
| 07/27/2026 | RSBU - Building Final | N/A | Not Ready | Coat all exterior plastic pipes. Threshold at garage shall be ADA standard. Hot water heater pipe shall be insulated with R3 insulation. Running water at primary bathroom lav. Provide refrigerant caps at condenser unit. Ensure unit is leveled. T stat shall be at 48”. AAV at kitchen requires aces panel. 7/27/2026AAV at kitchen requires access panel. Front Door handle not properly installed. 7/27/2026 |
| 08/06/2026 | ENGR Engineering Final | N/A | Partial Pass | Site is complete in accordance with approved plans. Outstanding conditions prevent full pass of Final inspection. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0725-00379
Permit Description: Blackhawk T933 - Beech (Model master plan TC-MDP-0923-01493)
Total Completed Inspections - 18
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/30/2026 | COT - RSPL - Rough Soil | Passed | 04/30/2026 Holding under test. Okay to backfill, shading required. |
|
| 04/30/2026 | COT - RSPL - Sewer | Passed | 04/30/2026 Holding under test with green tracer wire to HCS. Okay to backfill, shading required. |
|
| 04/30/2026 | COT - RSPL - Yard Water Line | Passed | 04/30/2026 Holding under test with blue tracer wire from meter to riser with PRV. Okay to backfill, shading required. |
|
| 05/08/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 05/08/2026 Approved per plan and reinforcements, ok to pour. |
|
| 05/08/2026 | COT - RSBU - Preslab | Passed | 05/08/2026 Approved per plan and reinforcements, ok to pour. |
|
| 05/08/2026 | COT - RSEL - Electrical Underground | Passed | ||
| 05/21/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Passed 5/21/26 | |
| 05/21/2026 | COT - RSBU - Roof Nailing | Passed | Passed 5/21/26 | |
| 06/02/2026 | COT - RSEL - Grounding/Bonding | Passed | approved | |
| 06/02/2026 | BULD - Electrical Clearance | Passed | Eco approved | |
| 06/02/2026 | COT - RSPL - Gas Pressure Test | Passed | ||
| 06/04/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 06/12/2026 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 07/24/2026 | COT - BULD - SWG Clearance | Passed | 7-24-26 SWG Clearance approved | |
| 07/27/2026 | COT - RSEL - Outdoor Lighting | Passed | ||
| 07/27/2026 | RSBU - Building Progress | Passed | ||
| 08/06/2026 | COT - RSEL - Electrical Final | Passed | 8-6-26: electrical final approved. | |
| 08/06/2026 | COT - RSME - Mechanical Final | Passed | 8-6-26: mechanical final approved. |