Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Address NEW:
2769 W BLACK CLOUD CT
Apply Date:
07/23/2024
Applicant:
James McMahon
Description:
Model Home w/ Guest House (Sleeping Quarters)

Permit Reviews

Permit Number - TC-MDP-0724-00809
Permit Status: Issued
Permit Description: Model Home w/ Guest House (Sleeping Quarters)
Start Date Submittal Complete Date Status  
07/25/2024 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 08/09/2024 REQUIRES RESUBMIT Review Details
01/28/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 02/19/2025 APPROVED Review Details
08/07/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/08/2025 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0724-00809
Permit Status: Issued
Permit Description: Model Home w/ Guest House (Sleeping Quarters)
Date Description Comments
01/28/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
07/23/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/23/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
07/23/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-MDP-0724-00809
Permite Description: Model Home w/ Guest House (Sleeping Quarters)
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
08/18/2025 BULD - Electrical Clearance N/A Re-inspection required Partial pass. Pending riser. 8/18/2025
08/26/2025 COT - RSBU - Interior Shear Bracing N/A Re-inspection required 8.26.25
Shear wall anchor bolts shall be no greater than 32oc throughout
Washers missing from multiple bolts throughout
Replace damaged floor plate at NE doorway near covered patio area
Nails over penetrate exterior sheathing in multiple areas

STOPPED INSPECTION. MORE ITEMS MAY BE ADDED

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0724-00809
Permit Description: Model Home w/ Guest House (Sleeping Quarters)
Total Completed Inspections - 13
Date Description Inspector Results Comments
05/21/2025 COT - RSPL - Rough Soil Passed
06/16/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
06/16/2025 COT - RSBU - Preslab Passed
06/16/2025 COT - RSEL - Electrical Underground Passed
08/18/2025 COT - RSPL - Sewer Passed Septic tie in and on test. Okay to backfill. Shading materials are required. 8/18/2025
08/21/2025 BULD - Electrical Clearance Passed Approved 400A service panel - ECO Clearance to TEP is required for the new service
08/25/2025 COT - RSPL - Yard Water Line Passed 8.25.25
Water pressure verified under test from meter.
Blue tracer wire present.
Depth verified.
APPROVED
08/26/2025 COT - RSBU - Roof Nailing Passed
08/27/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
12/08/2025 COT - FCON - Sprinkler - Final Passed
12/08/2025 COT - RSEL - Grounding/Bonding Passed
12/08/2025 COT - RSPL - Gas Pressure Test Passed
12/09/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed

Documents

File Name Document Type  
R89249747.2504528-A_GEI 07-21-25_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-LAS NUBES MODEL-CONSTRUCTION DRAWINGS_V2_V2.PDF DOCUMENTS VIEW