Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Interior Shear BracingĀ 

Permit Number - TC-MDP-0724-00809

Inspection Description - COT - RSBU - Interior Shear BracingĀ 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/26/2025 COT - RSBU - Interior Shear BracingĀ  Re-inspection required 8.26.25
Shear wall anchor bolts shall be no greater than 32oc throughout
Washers missing from multiple bolts throughout
Replace damaged floor plate at NE doorway near covered patio area
Nails over penetrate exterior sheathing in multiple areas

STOPPED INSPECTION. MORE ITEMS MAY BE ADDED