Permit: TC-MDP-0626-00452
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
6243 S BLUE ANGELS AV
Address NEW:
6243 S BLUE ANGELS AV
Apply Date:
08/19/2026
Applicant:
Celina Rodriguez
Description:
Cielo Reserves SFR Model 130.1262 (Model Master Plan TC-MDP-0526-00345)
Permit Reviews
Permit Number - TC-MDP-0626-00452
Permit Status: Inspections
Permit Description: Cielo Reserves SFR Model 130.1262 (Model Master Plan TC-MDP-0526-00345)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/25/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 08/28/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0626-00452
Permit Status: Inspections
Permit Description: Cielo Reserves SFR Model 130.1262 (Model Master Plan TC-MDP-0526-00345)
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 06/17/2026 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 06/17/2026 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 08/27/2026 | Prior to Final - Required Documents - Post-Installed Anchor Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0626-00452
Permit Status: Inspections
Permit Description: Cielo Reserves SFR Model 130.1262 (Model Master Plan TC-MDP-0526-00345)
| Date | Description | Comments |
|---|---|---|
| 06/17/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 06/17/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0626-00452
Permite Description: Cielo Reserves SFR Model 130.1262 (Model Master Plan TC-MDP-0526-00345)
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/16/2026 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
| COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Scheduled | ||
| BULD - Electrical Clearance | N/A | Scheduled | ||
| RSBU - Building Progress | N/A | Scheduled | ||
| COT - RSPL - Gas Pressure Test | N/A | Scheduled |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0626-00452
Permit Description: Cielo Reserves SFR Model 130.1262 (Model Master Plan TC-MDP-0526-00345)
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/09/2026 | COT - RSPL - Backwater Valve | Passed | 9-9-26 OK to backfill shading is required | |
| 09/09/2026 | COT - RSPL - Rough Soil | Passed | 9-9-26 OK to backfill shading is required | |
| 09/09/2026 | COT - RSPL - Yard Water Line | Passed | 9-9-26 OK to backfill shading is required | |
| 09/09/2026 | COT - RSPL - Sewer | Passed | 9-9-26 OK to backfill shading is required | |
| 09/17/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 9-17-26 all corrections have been made OK to pour | |
| 09/17/2026 | COT - RSBU - Preslab | Passed | 9-17-26 all corrections have been made OK to pour | |
| 09/29/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 9-29-26 shot pins are required to be no more than 6 inches from edge of non-loadbearing walls in 32 inches on center and any sill plate that is 12 inches or more required two shot pins, add shot pins at Marked locations. All locations are not marked please re-walk and add shot pins throughout* add sister stood at North wall due to broken stud* all other items have been corrected OK to proceed, will verify corrections at intermediate | |
| 09/29/2026 | COT - RSBU - Roof Nailing | Passed |
Scheduled Inspections
Scheduled Inspections - TC-MDP-0626-00452
Status: Inspections
Description: Cielo Reserves SFR Model 130.1262 (Model Master Plan TC-MDP-0526-00345)
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 10/09/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Scheduled | |
| 10/09/2026 | COT - RSPL - Gas Pressure Test | Scheduled | |
| 10/09/2026 | RSBU - Building Progress | Scheduled | |
| 10/09/2026 | BULD - Electrical Clearance | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.