Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Model Building Permit
Address:
9568 E MEOLA DR
Address NEW:
9568 E MEOLA DR
Apply Date:
06/18/2026
Applicant:
Celina Rodriguez
Description:
Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)

Permit Reviews

Permit Number - TC-MDP-0626-00442
Permit Status: Inspections
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Start Date Submittal Complete Date Status  
06/25/2026 SITE FROM MODEL PERMIT - SUBDIVISION v.1 07/02/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0626-00442
Permit Status: Inspections
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Total Outstanding Activity Conditions - 4
Date Name
06/16/2026 Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
06/16/2026 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
06/30/2026 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
06/30/2026 Post-Installed Anchor Inspection Report is required.

Conditions

Permit Number - TC-MDP-0626-00442
Permit Status: Inspections
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Date Description Comments
06/16/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
06/16/2026 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0626-00442
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Total Completed Inspections - 6
Date Description Inspector Results Comments
07/08/2026 COT - RSPL - Sewer Passed 07/08/2026
Holding under test. Ok to backfill. Backwater valve installed per site plan.
07/08/2026 COT - RSPL - Rough Soil Passed 07/08/2026
Holding under test. Ok to backfill.
07/08/2026 COT - RSPL - Yard Water Line Passed 07/08/2026
Holding under test. Ok to backfill.
07/16/2026 COT - RSBU - Preslab Passed 07/16/2026
Approved per plan and reinforcement. Okay to pour.
07/16/2026 COT - RSBU - Excavation/Rebar/Zoning Passed
07/16/2026 COT - RSEL - Electrical Underground Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
MIRADOR POINT - LOT 132 START_V1.PDF DOCUMENTS VIEW
MP 132 SIC-2026-06-18_V1.PDF DOCUMENTS VIEW