Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0626-00442

Parcel: 141461320


Addresses:

9568 E MEOLA DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
08/05/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 8-5-26: arrived on site at 837am and noted a mechanical worker offloading equipment into garage and working. Clip & nail inspection has not been approved nor can mechanical work be ongoing while we are attempting to conduct our inspection.
08/06/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 8-6-26: add nails per SN3/ detail 6-top plate splices, add nails to edge of sheathing at SW9/Bedroom 4, add nails to loose roof panels upstairs at marked locations, Per AD3/Detail 54-2" diameter washers are required with shot pins at 24" o.c., add shot pins at marked areas. Stopped inspection-additional items may be noted.
Note: 2nd floor not walked nor truss calc verification.
08/10/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Canceled 8-10-26: canceled by contractor.
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 8-13-26: add a34's at stair stringers, provide engineer fix for bottom top plate damage upstairs northwest corner, missing ltp4 clips missing at shear walls downstairs-see plans for details, fix blocking east upstairs shear wall, add nails at top plate splices per SN3/Detail 6, add tightens &2" washers at stair sill plate to concrete, remove roof paper at loose marked areas on roof panels and re- nail
08/21/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 8-21-26 All items have been corrected. OK to continue.