Permit Details

Status:
Inspections
Type:
Model Building Permit
Address NEW:
2142 E SUPERSONIC ST
Apply Date:
03/05/2026
Applicant:
Description:
Cielo Reserve 1465 SFR (Model master plan TC-MDP-0525-00294)

Permit Reviews

Permit Number - TC-MDP-0625-00369
Permit Status: Inspections
Permit Description: Cielo Reserve 1465 SFR (Model master plan TC-MDP-0525-00294)
Start Date Submittal Complete Date Status  
03/11/2026 SITE FROM MODEL PERMIT - SUBDIVISION v.1 03/18/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0625-00369
Permit Status: Inspections
Permit Description: Cielo Reserve 1465 SFR (Model master plan TC-MDP-0525-00294)
Total Outstanding Activity Conditions - 4
Date Name
03/12/2026 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
03/12/2026 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.
06/23/2025 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
06/23/2025 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/

Conditions

Permit Number - TC-MDP-0625-00369
Permit Status: Inspections
Permit Description: Cielo Reserve 1465 SFR (Model master plan TC-MDP-0525-00294)
Date Description Comments
06/23/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
06/23/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0625-00369
Permite Description: Cielo Reserve 1465 SFR (Model master plan TC-MDP-0525-00294)
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
07/01/2026 ENGR Engineering Final N/A Not Ready Conditions unsatisfied prior to final:
Epoxy Anchors special inspections
Post tension slab special inspections
HCS Cap in driveway is loose and not glued correctly.
07/01/2026 RSBU - Building Final N/A Re-inspection required 07/01/2026
Fill cavity and stucco above water heater flue terminated on outside wall.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0625-00369
Permit Description: Cielo Reserve 1465 SFR (Model master plan TC-MDP-0525-00294)
Total Completed Inspections - 20
Date Description Inspector Results Comments
03/27/2026 COT - RSPL - Rough Soil Passed 3.27.26
Approved
03/27/2026 COT - RSPL - Sewer Passed
03/27/2026 COT - RSPL - Yard Water Line Passed 3.27.26
Approved
04/08/2026 COT - RSBU - Excavation/Rebar/Zoning Passed 04/08/2026
Approved per plan, correction made to prior inspection. Ok to pour.
04/08/2026 COT - RSBU - Preslab Passed 04/08/2026
Approved per plan, correction made to prior inspection. Ok to pour.
04/08/2026 COT - RSEL - Electrical Underground Passed
04/15/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 04/15/2026
Approved per plan. Added anchor bolts and shot pins on interior sill plates 6" from edges at marked locations. Verified truss calcs and roof nailing.
04/15/2026 COT - RSBU - Roof Nailing Passed
04/29/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
04/29/2026 COT - RSEL - Grounding/Bonding Passed
04/29/2026 COT - RSPL - Gas Pressure Test Passed
04/29/2026 RSBU - Building Progress Passed
04/29/2026 BULD - Electrical Clearance Passed 4/29/2026
Clearance TEP ECO.
05/11/2026 COT - RSBU - Interior Shear Bracing Passed
06/18/2026 COT - BULD - SWG Clearance Passed
07/01/2026 COT - RSEL - Electrical Final Passed
07/01/2026 COT - RSEL - Outdoor Lighting Passed
07/01/2026 COT - RSME - Mechanical Final Passed
07/01/2026 COT - RSPL - Plumbing Final Passed
07/02/2026 RSBU - Building Final Passed 07/02/2026
Corrections made.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CIELO RESERVE - LOT 17 START_V1.PDF DOCUMENTS VIEW
CR 17 SIC-2026-03-05_V1.PDF DOCUMENTS VIEW