Permit Details

Status:
Issued
Type:
Model Building Permit
Apply Date:
08/15/2024
Applicant:
Dana Petty
Description:
SFR MERI150293 T21-M0067 REV1 roof covering change (Model master plan TC-MDP-0223-00542)

Permit Reviews

Permit Number - TC-MDP-0624-00764
Permit Status: Issued
Permit Description: SFR MERI150293 T21-M0067 REV1 roof covering change (Model master plan TC-MDP-0223-00542)
Start Date Submittal Complete Date Status  
08/19/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 08/23/2024 APPROVED Review Details
01/30/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 01/31/2025 APPROVED Review Details
11/15/2024 SITE FROM MODEL PERMIT - PRODUCTION REVISION v.1 11/26/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0624-00764
Permit Status: Issued
Permit Description: SFR MERI150293 T21-M0067 REV1 roof covering change (Model master plan TC-MDP-0223-00542)
Date Description Comments
08/21/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
08/21/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
01/31/2025 Post-Installed Anchor Inspection Report is required.
08/21/2024 Post-Tension Inspection Report is required.
06/28/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
06/28/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
08/21/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0624-00764
Permit Description: SFR MERI150293 T21-M0067 REV1 roof covering change (Model master plan TC-MDP-0223-00542)
Total Completed Inspections - 13
Date Description Inspector Results Comments
11/21/2024 COT - RSPL - Backwater Valve Passed Okay to backfill. Shading required. 11/21/2024
11/21/2024 COT - RSPL - Rough Soil Passed Okay to backfill. Shading required. 11/21/2024
11/21/2024 COT - RSPL - Sewer Passed Okay to backfill. Shading required. 11/21/2024
11/21/2024 COT - RSPL - Yard Water Line Passed Okay to backfill. Shading required. 11/21/2024
12/04/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Concrete forms are set, hold downs and masa clips are attached to form as required, post tension cabling is evenly spaced per plan and properly supported off of ground, rebar reinforcement is in place as required per plan, Ufer ground is in place, all underground plumbing pipes are wrapped with foam, and underground electrical is in place for kitchen island. Okay to proceed with concrete pour.
12/04/2024 COT - RSBU - Preslab Passed Concrete forms are set, hold downs and masa clips are attached to form as required, post tension cabling is evenly spaced per plan and properly supported off of ground, rebar reinforcement is in place as required per plan, Ufer ground is in place, all underground plumbing pipes are wrapped with foam, and underground electrical is in place for kitchen island. Okay to proceed with concrete pour.
12/04/2024 COT - RSEL - Electrical Underground Passed Concrete forms are set, hold downs and masa clips are attached to form as required, post tension cabling is evenly spaced per plan and properly supported off of ground, rebar reinforcement is in place as required per plan, Ufer ground is in place, all underground plumbing pipes are wrapped with foam, and underground electrical is in place for kitchen island. Okay to proceed with concrete pour.
12/23/2024 COT - RSBU - Exterior Clips/Sheathing Passed
12/23/2024 COT - RSBU - Roof Nailing Passed
01/28/2025 COT - RSEL - Grounding/Bonding Passed 1-28-25, grounding/bonding approved
01/28/2025 BULD - Electrical Clearance Passed 1-28-25, panel approved to be energized. ECO clearance sent to TEP
01/28/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 1-28-25, residential intermediate approved. Okay to continue with construction.
01/28/2025 COT - RSPL - Gas Pressure Test Passed 1-28-25, approved

Documents

File Name Document Type  
152030 PT LOT 93 COMPLETE-2025-01-27_V1.PDF DOCUMENTS VIEW