Inspection Status: Passed

Inspection History: COT - RSBU - Preslab  

Permit Number - TC-MDP-0624-00764

Inspection Description - COT - RSBU - Preslab  

Inspection Status - Passed

Date Description Inspector Results Comments
12/04/2024 COT - RSBU - Preslab   Passed Concrete forms are set, hold downs and masa clips are attached to form as required, post tension cabling is evenly spaced per plan and properly supported off of ground, rebar reinforcement is in place as required per plan, Ufer ground is in place, all underground plumbing pipes are wrapped with foam, and underground electrical is in place for kitchen island. Okay to proceed with concrete pour.