Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Apply Date:
08/10/2023
Applicant:
Andrea Flood
Description:
SFR F40G22 T22-M0025 Revision-Truss Calcs

Permit Reviews

Permit Number - TC-MDP-0623-01185
Permit Status: Inspections complete
Permit Description: SFR F40G22 T22-M0025 Revision-Truss Calcs
Start Date Submittal Complete Date Status  
08/11/2023 SITE FROM MODEL PERMIT - PRODUCTION v.1 08/15/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0623-01185
Permit Status: Inspections complete
Permit Description: SFR F40G22 T22-M0025 Revision-Truss Calcs
Total Outstanding Activity Conditions - 7
Date Name
07/20/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
08/11/2023 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
08/11/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
08/11/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
08/11/2023 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
08/15/2023 Post-Tension Inspection Report is required.
08/15/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-MDP-0623-01185
Permit Status: Inspections complete
Permit Description: SFR F40G22 T22-M0025 Revision-Truss Calcs
Date Description Comments
06/27/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/20/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0623-01185
Permite Description: SFR F40G22 T22-M0025 Revision-Truss Calcs
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
03/21/2024 COT - RSEL - Electrical Final N/A Re-inspection required Garage and exterior outlet receptacles must run on their own circuits per E1 plans, countertop right side of range missing gfci receptacle per E3901.4, kitchen outlets missing plate covers. Not ready. Stopped inspection. More items may be added.
03/21/2024 COT - RSME - Mechanical Final N/A Not Ready Not ready.
03/21/2024 COT - RSPL - Plumbing Final N/A Not Ready Not ready.
03/21/2024 RSBU - Building Final N/A Re-inspection required Garage and exterior outlet receptacles must run on their own circuits per E1 plans, countertop right side of range missing gfci receptacle per E3901.4, kitchen outlets missing plate covers. Not ready. Stopped inspection. More items may be added.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0623-01185
Permit Description: SFR F40G22 T22-M0025 Revision-Truss Calcs
Total Completed Inspections - 21
Date Description Inspector Results Comments
09/15/2023 COT - RSPL - Rough Soil Passed
09/15/2023 COT - RSPL - Sewer Passed
09/22/2023 COT - RSBU - Excavation/Rebar/Zoning Passed
09/22/2023 COT - RSBU - Preslab Passed
09/22/2023 COT - RSEL - Electrical Underground Passed
09/22/2023 COT - RSEL - Grounding/Bonding Passed
10/20/2023 COT - RSBU - Exterior Clips/Sheathing Passed 10/20/23 Missing some anchor bolts front shear wall will check at intermediate
10/20/2023 COT - RSBU - Roof Nailing Passed 10/20/23 Missing some anchor bolts front shear wall will check at intermediate
12/15/2023 BULD - Electrical Clearance Passed TEP ECO
12/15/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
12/15/2023 COT - RSPL - Gas Pressure Test Passed
12/15/2023 COT - RSPL - Yard Water Line Passed
01/03/2024 COT - RSBU - Interior Shear Bracing Passed
03/18/2024 COT - BULD - SWG Clearance Passed Gas pipe has passed pressure test, gas line valves are in place for kitchen stove, laundry room dryer, and garage for installed water heater. Water heater line has a sediment trap installed on gas line.
03/21/2024 COT - RSEL - Outdoor Lighting Passed
03/21/2024 RSBU - Building Progress Passed
03/21/2024 ENGR Engineering Final Passed
03/26/2024 COT - RSEL - Electrical Final Passed
03/26/2024 COT - RSME - Mechanical Final Passed
03/26/2024 COT - RSPL - Plumbing Final Passed
03/26/2024 RSBU - Building Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
1_APPLICATION_V1.PDF DOCUMENTS VIEW
1_SITEPLAN_V1.PDF DOCUMENTS VIEW
1_SPECIAL INSPECTION CERT-2023-08-10_V1.PDF DOCUMENTS VIEW