Permit: TC-MDP-0623-01173
Permit Details
Apply Date:
01/02/2025
Applicant:
Celina Rodriguez
Description:
SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Permit Reviews
Permit Number - TC-MDP-0623-01173
Permit Status: Inspections
Permit Description: SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/14/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 01/22/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0623-01173
Permit Status: Inspections
Permit Description: SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
01/14/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
01/15/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
01/15/2025 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
01/15/2025 | Post-Installed Anchor Inspection Report is required. |
01/15/2025 | Post-Tension Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0623-01173
Permit Status: Inspections
Permit Description: SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Date | Description | Comments |
---|---|---|
01/14/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
06/22/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0623-01173
Permite Description: SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/11/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 1. Bang plates needed throughout. 2. Vent on West wall second floor bathroom needs Boca plate on sill and on top plate, also needs to be sealed/flashed through roof. 3. Pancake box in master bathroom above sink is overloaded. 4. Attic light switch needs to be facing attic access, current location is hard to find in the dark. 5. Return air flex for bedroom 3 is not attached to Air handler. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0623-01173
Permit Description: SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Total Completed Inspections - 11
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/24/2025 | COT - RSPL - Sewer | Passed | 1/24/25 pass | |
01/24/2025 | COT - RSPL - Rough Soil | Passed | 1/24/25 pass | |
01/24/2025 | COT - RSPL - Yard Water Line | Passed | 1/24/25 pass | |
02/04/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 2/4/25 passed, rebar and hold downs per plan, ok to pour concrete | |
02/04/2025 | COT - RSEL - Electrical Underground | Passed | 2/4/25 passed, rebar and hold downs per plan, ok to pour concrete | |
02/04/2025 | COT - RSBU - Preslab | Passed | 2/4/25 passed, rebar and hold downs per plan, ok to pour concrete | |
02/04/2025 | COT - RSEL - Grounding/Bonding | Passed | 2/4/25 passed, rebar and hold downs per plan, ok to pour concrete | |
02/04/2025 | COT - RSPL - Backwater Valve | Passed | 2/4/25 passed | |
02/20/2025 | COT - RSBU - Roof Nailing | Passed | 2/19/25 pass | |
02/21/2025 | COT - RSBU - Exterior Clips/Sheathing | Passed | 2/21/25: Brackets have been installed on stairwell landing floor joists, upstairs shear walls has been properly secured to studs, and bottom plate is properly nailed off. Okay to proceed with rough-in of mechanical, electrical, and plumbing. | |
03/11/2025 | COT - RSPL - Gas Pressure Test | Passed |
Scheduled Inspections
Scheduled Inspections - TC-MDP-0623-01173
Status: Inspections
Description: SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Scheduled Date | Description | Entered By | Entered Date |
---|---|---|---|
03/13/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.