Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0623-01173
Permit Details
Apply Date:
01/02/2025
Applicant:
Celina Rodriguez
Description:
SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Permit Reviews
Permit Number - TC-MDP-0623-01173
Permit Status: Inspections
Permit Description: SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/14/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 01/22/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0623-01173
Permit Status: Inspections
Permit Description: SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
01/14/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
01/15/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
01/15/2025 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
01/15/2025 | Post-Installed Anchor Inspection Report is required. |
01/15/2025 | Post-Tension Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0623-01173
Permit Status: Inspections
Permit Description: SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Date | Description | Comments |
---|---|---|
01/14/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
06/22/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0623-01173
Permit Description: SFR BT2010-30 T22-M0010 (Model master plan TC-MDP-0623-01161)
Total Completed Inspections - 8
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/24/2025 | COT - RSPL - Sewer | Passed | 1/24/25 pass | |
01/24/2025 | COT - RSPL - Rough Soil | Passed | 1/24/25 pass | |
01/24/2025 | COT - RSPL - Yard Water Line | Passed | 1/24/25 pass | |
02/04/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 2/4/25 passed, rebar and hold downs per plan, ok to pour concrete | |
02/04/2025 | COT - RSEL - Electrical Underground | Passed | 2/4/25 passed, rebar and hold downs per plan, ok to pour concrete | |
02/04/2025 | COT - RSBU - Preslab | Passed | 2/4/25 passed, rebar and hold downs per plan, ok to pour concrete | |
02/04/2025 | COT - RSEL - Grounding/Bonding | Passed | 2/4/25 passed, rebar and hold downs per plan, ok to pour concrete | |
02/04/2025 | COT - RSPL - Backwater Valve | Passed | 2/4/25 passed |