Permit: TC-MDP-0526-00366
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
9739 E PANOPEIA DR
Address NEW:
9739 E PANOPEIA DR
Apply Date:
07/07/2026
Applicant:
Celina Rodriguez
Description:
Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
Permit Reviews
Permit Number - TC-MDP-0526-00366
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/13/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 07/20/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0526-00366
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 05/26/2026 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 05/26/2026 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 07/20/2026 | Post-Installed Anchor Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0526-00366
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
| Date | Description | Comments |
|---|---|---|
| 05/26/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 05/26/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0526-00366
Permite Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/13/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 8-13-26: add anchor bolts to marked locations-an anchor bolt is required at shear walls within 12" at the ends of plates, add shot pins to marked areas, missing. RSP4's at the end of wall northwest corner, nail shot pins flush at the northwest exterior wall & at the island, nail loose roof panels at bedroom 1-see marked locations. |
| 08/13/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 8-13-26: add anchor bolts to marked locations-an anchor bolt is required at shear walls within 12" at the ends of plates, add shot pins to marked areas, missing. RSP4's at the end of wall northwest corner, nail shot pins flush at the northwest exterior wall & at the island, nail loose roof panels at bedroom 1-see marked locations. |
| COT - RSBU - Interior Shear Bracing | N/A | Scheduled |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0526-00366
Permit Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2026 | COT - RSPL - Backwater Valve | Passed | Okay to backfill. Shading required. 7/23/2026 | |
| 07/23/2026 | COT - RSPL - Rough Soil | Passed | Okay to backfill. Shading required. 7/23/2026 | |
| 07/23/2026 | COT - RSPL - Sewer | Passed | Okay to backfill. Shading required. 7/23/2026 | |
| 07/23/2026 | COT - RSPL - Yard Water Line | Passed | Okay to backfill. Shading required. 7/23/2026 | |
| 08/04/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 08/04/2026 | COT - RSBU - Preslab | Passed | 08/04/2026 Approved per plan and reinforcement. Okay for concrete placement. |
|
| 08/04/2026 | COT - RSEL - Electrical Underground | Passed | ||
| 08/17/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 8-17-26: okay to continue with MEP's-nail shot pins at northwest bedroom flush.We will verify at intermediates and prior to covering exterior wall. | |
| 08/17/2026 | COT - RSBU - Roof Nailing | Passed | 8-17-26: okay to dry-in roof. | |
| 09/03/2026 | COT - RSPL - Gas Pressure Test | Passed | 9-3-26 gas pressure test approved | |
| 09/03/2026 | BULD - Electrical Clearance | Passed | 9-3-26 ECO clearance approved | |
| 09/08/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 9-8-26 all items have been corrected. Okay to proceed |
Scheduled Inspections
Scheduled Inspections - TC-MDP-0526-00366
Status: Inspections
Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 09/28/2026 | COT - RSBU - Interior Shear Bracing | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.