Permit: TC-MDP-0526-00366

Parcel: 141155520


Addresses:

9739 E PANOPEIA DR

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 8-13-26: add anchor bolts to marked locations-an anchor bolt is required at shear walls within 12" at the ends of plates, add shot pins to marked areas, missing. RSP4's at the end of wall northwest corner, nail shot pins flush at the northwest exterior wall & at the island, nail loose roof panels at bedroom 1-see marked locations.
08/17/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 8-17-26: okay to continue with MEP's-nail shot pins at northwest bedroom flush.We will verify at intermediates and prior to covering exterior wall.