Permit Details

Status:
Inspections
Type:
Model Building Permit
Address NEW:
10021 E LEBARON DR
Apply Date:
06/01/2026
Applicant:
Celina Rodriguez
Description:
Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)

Permit Reviews

Permit Number - TC-MDP-0526-00362
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
Start Date Submittal Complete Date Status  
06/03/2026 SITE FROM MODEL PERMIT - SUBDIVISION v.1 06/10/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0526-00362
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
Total Outstanding Activity Conditions - 4
Date Name
05/26/2026 Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
05/26/2026 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
06/09/2026 Post-Installed Anchor Inspection Report is required.
06/09/2026 Post-Tension Inspection Report is required.

Conditions

Permit Number - TC-MDP-0526-00362
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
Date Description Comments
05/26/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
05/26/2026 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0526-00362
Permite Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
07/15/2026 COT - RSBU - Roof Nailing N/A Re-inspection required 7/15/26: nailing at shear wall over-spaced sw9 6/12 (fasteners shall be no closer than 3/8" from edge), properly secure king stud to trimmer per detail 13A, missing nails at rsp4 throughout at exterior, opening at entrance must have 2x6 header with DTC clip, anchor bolts must be placed no closer than 3.5" from edge of plate, shiners at shearwall, anchor bolts at sw11 must be 23" o.c with 3x3 washer plate, fasteners at shearwall shall not penemore than 1/8" and shall be further than 3/8" from edge, sw11 4/12" fasteners spacing throughout, rsp4 required at cripple studs and headers at window openings, 2 anchor bolts required at sill plate greater than 12", anchor shall be placed in middle third of sill plate, back patio requires (4)16 d nails at 24" o.c, sw9 at bedroom requires prop fasteners 6/12, garage satraps require (2) cs14 with opening greater than 9'. STOPPED INSPECTION MORE ITEMS MAY BE ADDED
(Inside of home was not walked)
07/15/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 7/15/26: nailing at shear wall over-spaced sw9 6/12 (fasteners shall be no closer than 3/8" from edge), properly secure king stud to trimmer per detail 13A, missing nails at rsp4 throughout at exterior, opening at entrance must have 2x6 header with DTC clip, anchor bolts must be placed no closer than 3.5" from edge of plate, shiners at shearwall, anchor bolts at sw11 must be 23" o.c with 3x3 washer plate, fasteners at shearwall shall not penemore than 1/8" and shall be further than 3/8" from edge, sw11 4/12" fasteners spacing throughout, rsp4 required at cripple studs and headers at window openings, 2 anchor bolts required at sill plate greater than 12", anchor shall be placed in middle third of sill plate, back patio requires (4)16 d nails at 24" o.c, sw9 at bedroom requires prop fasteners 6/12, garage satraps require (2) cs14 with opening greater than 9'. STOPPED INSPECTION MORE ITEMS MAY BE ADDED
(Inside of home was not walked)

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0526-00362
Permit Description: Mirador Ridge Blossom 1728 Plan (Model master plan TC-MDP-0725-00411)
Total Completed Inspections - 7
Date Description Inspector Results Comments
06/24/2026 COT - RSPL - Backwater Valve Passed
06/24/2026 COT - RSPL - Rough Soil Passed
06/24/2026 COT - RSPL - Sewer Passed
06/24/2026 COT - RSPL - Yard Water Line Passed
07/02/2026 COT - RSBU - Preslab Passed 07/02/2026
Approved per plan. Okay for concrete placement.
07/02/2026 COT - RSEL - Electrical Underground Passed
07/02/2026 COT - RSBU - Excavation/Rebar/Zoning Passed