Permit: TC-MDP-0524-00617
Permit Details
Apply Date:
05/13/2024
Applicant:
Daria Hopkins
Description:
SFR MER1402190 T21-M0078
Permit Reviews
Permit Number - TC-MDP-0524-00617
Permit Status: Inspections
Permit Description: SFR MER1402190 T21-M0078
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/01/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 08/07/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0524-00617
Permit Status: Inspections
Permit Description: SFR MER1402190 T21-M0078
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
05/13/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
08/07/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
08/07/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
08/07/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
08/07/2024 | Post-Tension Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0524-00617
Permit Status: Inspections
Permit Description: SFR MER1402190 T21-M0078
Date | Description | Comments |
---|---|---|
05/13/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
08/07/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0524-00617
Permite Description: SFR MER1402190 T21-M0078
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/27/2024 | COT - RSEL - Grounding/Bonding | N/A | Partial Pass | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0524-00617
Permit Description: SFR MER1402190 T21-M0078
Total Completed Inspections - 8
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/18/2024 | COT - RSPL - Yard Water Line | Passed | 11-18-24, underground plumbing, sewer connection, and main water line verified as per approved plans. Okay to backfill-provide shading. | |
11/18/2024 | COT - RSPL - Sewer | Passed | 11-18-24, underground plumbing, sewer connection, and main water line verified as per approved plans. Okay to backfill-provide shading. | |
11/18/2024 | COT - RSPL - Rough Soil | Passed | 11-18-24, underground plumbing, sewer connection, and main water line verified as per approved plans. Okay to backfill-provide shading. | |
11/27/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. | |
11/27/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. | |
11/27/2024 | COT - RSEL - Electrical Underground | Passed | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. | |
12/16/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 12/16/24 corrections were made. Continued the inspection to ensure nothing else was missed. PASS | |
12/16/2024 | COT - RSBU - Roof Nailing | Passed | 12/16/24 corrections were made. Continued the inspection to ensure nothing else was missed. PASS |