Permit: TC-MDP-0523-01018
Permit Details
Apply Date:
09/12/2023
Applicant:
Daria Hopkins
Description:
SFR MERI156021 T21-M0063
Permit Reviews
Permit Number - TC-MDP-0523-01018
Permit Status: Complete
Permit Description: SFR MERI156021 T21-M0063
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/13/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 09/14/2023 | APPROVED |
09/18/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/18/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0523-01018
Permit Status: Complete
Permit Description: SFR MERI156021 T21-M0063
Date | Description | Comments |
---|---|---|
09/13/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
09/13/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
09/13/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
09/13/2023 | Post-Tension Inspection Report is required. | |
05/11/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
09/18/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ | |
09/13/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
09/13/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0523-01018
Permite Description: SFR MERI156021 T21-M0063
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/07/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | GEC not properly connected to ufer, open chase right side of garage, fire foam top plates of gas lines throughout, complete wiring for can light in bathroom, 4-gang boxes must be secured, dwv not under test, add nail plate to back side of range vent, pex lines within 12” of can lights must be insulated, complete wiring in master bedroom ceiling, wiring not complete for outlet in low voltage box, nail plate needed at bedroom 2. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0523-01018
Permit Description: SFR MERI156021 T21-M0063
Total Completed Inspections - 22