Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-MDP-0523-01018

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
02/07/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required GEC not properly connected to ufer, open chase right side of garage, fire foam top plates of gas lines throughout, complete wiring for can light in bathroom, 4-gang boxes must be secured, dwv not under test, add nail plate to back side of range vent, pex lines within 12” of can lights must be insulated, complete wiring in master bedroom ceiling, wiring not complete for outlet in low voltage box, nail plate needed at bedroom 2.
02/09/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed