Permit: TC-MDP-0426-00204
Permit Details
Status:
In Review
Type:
Model Building Permit
Address:
487 N COVILLE DR
Address NEW:
487 N COVILLE DR
Apply Date:
09/15/2026
Applicant:
Celina Rodriguez
Description:
Enclaves at Tumamoc 1609 Plan (Model Master Plan TC-MDP-1225-00793)
Permit Reviews
Permit Number - TC-MDP-0426-00204
Permit Status: In review
Permit Description: Enclaves at Tumamoc 1609 Plan (Model Master Plan TC-MDP-1225-00793)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/17/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 09/22/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0426-00204
Permit Status: In review
Permit Description: Enclaves at Tumamoc 1609 Plan (Model Master Plan TC-MDP-1225-00793)
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 04/01/2026 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 04/01/2026 | MANUAL J |
| 04/01/2026 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 09/22/2026 | Prior to Final - Special Inspections - SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0426-00204
Permit Status: In review
Permit Description: Enclaves at Tumamoc 1609 Plan (Model Master Plan TC-MDP-1225-00793)
| Date | Description | Comments |
|---|---|---|
| 04/01/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 04/01/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: In Review
Permit Number: TC-MDP-0426-00204
Permite Description: Enclaves at Tumamoc 1609 Plan (Model Master Plan TC-MDP-1225-00793)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/12/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 11/12/2026 Nail through pex left of garage. Main line. Staple nm cable left of garage marked area. Add nail plates to marked areas. Seal electrical raceway. Abs has been punctured at hall bath 2nd floor. Add blocking near line sets through second floor and primary condensation line. Re secure vent line at primary room right entry. Replace fresh air intake due to water trapped. |
Completed Inspections
Permit Status: In Review
Permit Number: TC-MDP-0426-00204
Permit Description: Enclaves at Tumamoc 1609 Plan (Model Master Plan TC-MDP-1225-00793)
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2026 | COT - RSPL - Rough Soil | Passed | 10/06/2026 Holding under test. Okay to backfill, shading required. |
|
| 10/06/2026 | COT - RSPL - Sewer | Passed | 10/06/2026 Holding under test. Okay to backfill, shading required. |
|
| 10/06/2026 | COT - RSPL - Yard Water Line | Passed | 10/06/2026 Holding under test. Okay to backfill, shading required. |
|
| 10/12/2026 | COT - RSBU - Preslab | Passed | Passed | |
| 10/12/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Passed | |
| 10/12/2026 | COT - RSEL - Electrical Underground | Passed | Passed | |
| 10/28/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 10/27/2026 Corrections made. Walked second floor and verified added sister stud to damaged stud at rear west wall as marked. Added fasteners to loose roof panels. |
|
| 10/28/2026 | COT - RSBU - Roof Nailing | Passed | 10/27/2026 Corrections made. Walked second floor and verified added sister stud to damaged stud at rear west wall as marked. Added fasteners to loose roof panels. |
|
| 11/12/2026 | BULD - Electrical Clearance | Passed | Clearance for TEP ECO. 11/12/2026 | |
| 11/12/2026 | COT - RSPL - Gas Pressure Test | Passed |
Scheduled Inspections
Scheduled Inspections - TC-MDP-0426-00204
Status: In Review
Description: Enclaves at Tumamoc 1609 Plan (Model Master Plan TC-MDP-1225-00793)
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 11/16/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.