Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
In Review
Type:
Model Building Permit
Address NEW:
348 N BOATHOUSE LN
Apply Date:
07/15/2026
Applicant:
Celina Rodriguez
Description:
Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)

Permit Reviews

Permit Number - TC-MDP-0426-00198
Permit Status: In review
Permit Description: Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
Start Date Submittal Complete Date Status  
07/17/2026 SITE FROM MODEL PERMIT - SUBDIVISION v.1 07/28/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0426-00198
Permit Status: In review
Permit Description: Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
Total Outstanding Activity Conditions - 4
Date Name
04/01/2026 Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
04/01/2026 MANUAL J
04/01/2026 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
07/23/2026 Prior to Final - Required Documents - Post-Installed Anchor Inspection Report is required.

Conditions

Permit Number - TC-MDP-0426-00198
Permit Status: In review
Permit Description: Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
Date Description Comments
04/01/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
04/01/2026 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: In Review
Permit Number: TC-MDP-0426-00198
Permite Description: Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/24/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Not Ready 9/24/2026 Ensure ground screw is making full contact with metal box. (Exterior) Provide hangers at every 4’ to three in line next to shower p trap. Caulk marked exterior penetrations. Secure pex at powder room. Secure exhaust duct every 4’. Add nail plates to marked areas. Fire foam electrical line at landing. Provide proper listed supports for both condensation lines. Currently using nails. Tape all tares in ductwork. Receptacle to close to shower in master bathroom. Need to be relocated. Fire foam electrical line in 1st bedroom marked areas. Fire foam penetration in north west bedroom corner. Fire foam abs line in hall bathroom. Add Boca plate to and line in laundry room.

Completed Inspections

Permit Status: In Review
Permit Number: TC-MDP-0426-00198
Permit Description: Enclaves at Tumamoc 1765 Plan (Model Master Plan TC-MDP-1225-00794)
Total Completed Inspections - 12
Date Description Inspector Results Comments
08/05/2026 COT - RSPL - Rough Soil Passed
08/05/2026 COT - RSPL - Sewer Passed
08/05/2026 COT - RSPL - Yard Water Line Passed
08/12/2026 COT - RSBU - Preslab Passed
08/12/2026 COT - RSBU - Excavation/Rebar/Zoning Passed
08/27/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Passed
08/27/2026 COT - RSBU - Roof Nailing Passed Passed
09/24/2026 COT - RSPL - Gas Pressure Test Passed
09/24/2026 BULD - Electrical Clearance Passed Clearance to TEP ECO. 9/24/2026
09/28/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
10/12/2026 COT - RSBU - Interior Shear Bracing Passed Passed
11/13/2026 COT - BULD - SWG Clearance Passed Clearance for Southwest Gas. 11/13/2026

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
TUMAMOC - LOT 20 START REVISED_V1.PDF DOCUMENTS VIEW
TUMAMOC 20 SIC-2026-07-15_V1.PDF DOCUMENTS VIEW