Inspection Status: Not Ready
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 09/24/2026 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Not Ready |
9/24/2026 Ensure ground screw is making full contact with metal box. (Exterior) Provide hangers at every 4’ to three in line next to shower p trap. Caulk marked exterior penetrations. Secure pex at powder room. Secure exhaust duct every 4’. Add nail plates to marked areas. Fire foam electrical line at landing. Provide proper listed supports for both condensation lines. Currently using nails. Tape all tares in ductwork. Receptacle to close to shower in master bathroom. Need to be relocated. Fire foam electrical line in 1st bedroom marked areas. Fire foam penetration in north west bedroom corner. Fire foam abs line in hall bathroom. Add Boca plate to and line in laundry room. |
| 09/28/2026 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Passed |
|