Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Address:
1349 E RENS RD
Address NEW:
1349 E RENS RD
Apply Date:
09/08/2023
Applicant:
Abraham Andraux
Description:
Carlos MP 1440 SFR (Model master plan TC-MDP-0823-01449)

Permit Reviews

Permit Number - TC-MDP-0424-00527
Permit Status: Complete
Permit Description: Carlos MP 1440 SFR (Model master plan TC-MDP-0823-01449)
Start Date Submittal Complete Date Status  
05/23/2024 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 05/29/2024 APPROVED Review Details
04/29/2024 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 05/14/2024 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-MDP-0424-00527
Permit Status: Complete
Permit Description: Carlos MP 1440 SFR (Model master plan TC-MDP-0823-01449)
Date Description Comments
05/29/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
04/26/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
04/26/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-0424-00527
Permite Description: Carlos MP 1440 SFR (Model master plan TC-MDP-0823-01449)
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
08/01/2024 COT - RSPL - Rough Soil N/A Re-inspection required 8/1/24: please provide approved set of plans.
08/01/2024 COT - RSPL - Sewer N/A Re-inspection required 8/1/24: please provide approved set of plans.
08/01/2024 COT - RSPL - Yard Water Line N/A Re-inspection required 8/1/24: please provide approved set of plans.
11/14/2024 COT - RSPL - Gas Pressure Test N/A Not Applicable
11/15/2024 COT - RSBU - Interior Shear Bracing N/A Not Applicable
11/14/2024 COT - BULD - SWG Clearance N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0424-00527
Permit Description: Carlos MP 1440 SFR (Model master plan TC-MDP-0823-01449)
Total Completed Inspections - 14
Date Description Inspector Results Comments
08/05/2024 COT - RSBU - Excavation/Rebar/Zoning Passed 8/5/24: Reinforcement per plan ok to proceed
08/05/2024 COT - RSBU - Preslab Passed 8/5/24: Reinforcement per plan ok to proceed
08/28/2024 COT - RSBU - Roof Nailing Passed
08/29/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 8/27/24: Anchor bolts missing 12" from edge of sill plate. Anchor bolts must be properly fastened throughout house, sheathing not fastened per schedule throughout, H2.5 Clips missing and not properly fastened, Shot pins at at interior non bearing walls must be space no greater than 24" o.c and no more than 6" from edge of bottom plate, nailing at sheathing must be 3/8" from edge and not penetrate more than 1/8".
8/28/24: not ready.
8/29/24: corrections made ok to proceed.
09/10/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Approved. 9/10/2024
09/19/2024 BULD - Electrical Clearance Passed Approved new 200A service panel - ECO Clearance to TEP is required for construction power
09/19/2024 COT - RSEL - Electrical Underground Passed
11/15/2024 COT - RSEL - Electrical Final Passed 11/15/24 pass
11/14/2024 COT - RSEL - Grounding/Bonding Passed 11/14/24 pass
11/14/2024 COT - RSEL - Outdoor Lighting Passed 11/14/24 pass
11/14/2024 ENGR Engineering Final Passed CO Ready
11/15/2024 COT - RSME - Mechanical Final Passed 11/15/24. Pass
11/15/2024 COT - RSPL - Plumbing Final Passed 11/15/24 corrections have been made
11/15/2024 RSBU - Building Final Passed 11/15/24 corrections have been made

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
1_CARLOS MODEL_MJCALCS_V2.PDF DOCUMENTS VIEW
1_CORRECTED_SITE_PLAN_V2.PDF DOCUMENTS VIEW