Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0424-00527

Parcel: 140241690


Addresses:

1349 E RENS RD

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof NailingĀ 

Date Description Inspector Results Comments
08/27/2024 COT - RSBU - Roof NailingĀ  Re-inspection required 8/27/24: Anchor bolts missing 12" from edge of sill plate. Anchor bolts must be properly fastened throughout house, sheathing not fastened per schedule throughout, H2.5 Clips missing and not properly fastened, Shot pins at at interior non bearing walls must be space no greater than 24" o.c and no more than 6" from edge of bottom plate, nailing at sheathing must be 3/8" from edge and not penetrate more than 1/8".
08/28/2024 COT - RSBU - Roof NailingĀ  Passed