Permit Reviews
Permit Number - TC-MDP-0424-00526
Permit Status: Issued
Permit Description: American Samoa Model Plan La Escalera
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/26/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 05/01/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0424-00526
Permit Status: Issued
Permit Description: American Samoa Model Plan La Escalera
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
04/25/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
04/30/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
04/30/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
04/30/2024 | Post-Tension Inspection Report is required. |
04/30/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0424-00526
Permit Status: Issued
Permit Description: American Samoa Model Plan La Escalera
Date | Description | Comments |
---|---|---|
04/25/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
04/30/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-MDP-0424-00526
Permite Description: American Samoa Model Plan La Escalera
Total Outstanding Inspections - 3
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/28/2024 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
10/28/2024 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
10/29/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 10/29/24: box fill at garage exterior lighting is exceeding max fill (6 Cubic inches), nail plate required at garage at electrical and kitchen walls and top plates (throughout house first and second floor), circuits installed are not meeting required circuits on approved panel schedule, receptacle missing per plans at laundry room, NM sheathing must extend 1/2" into box at all fixtures ( under stair way kitchen switch ), circuit A-1 at family room is calling for 20Amp breaker (requires 12Awg wiring), wiring size not per plan throughout, mechanical not attached to register upstairs bedroom, all thermostat shall be no higher than 48" o.c above finish floor. STOPPED INSPECTION MORE ITEMS MAY BE ADDED |
Completed Inspections
Permit Status: Issued
Permit Number: TC-MDP-0424-00526
Permit Description: American Samoa Model Plan La Escalera
Total Completed Inspections - 9
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/17/2024 | COT - RSPL - Rough Soil | Passed | 6/17/24: Underground plumbing is exposed, green tracer wire is installed, system is under water test with no leaks. Okay to shade pipe and backfill trenches. | |
06/17/2024 | COT - RSPL - Yard Water Line | Passed | 6/17/24: Main water line has been exposed, line is under 40# of air pressure with no leaks. Okay to shade pipe and backfill trench. | |
06/25/2024 | COT - RSEL - Electrical Underground | Passed | ||
06/25/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
06/26/2024 | COT - RSBU - Preslab | Passed | ||
06/26/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
08/02/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | All shear walls are properly secured to concrete floor with shear brackets with titan bolts and properly plywood sheathing is properly secured to studs per plan. All interior and exterior wall bottom plates are secured to concrete floor with red heads, masa clips, or titan bolts. Okay to proceed with rough in. | |
08/02/2024 | COT - RSBU - Roof Nailing | Passed | Roof trusses are properly secured to top plate with nails and H2.5 clips. Plywood sheathing is properly secured to roof trusses with nails and staples. Okay to proceed with rough-in. | |
10/16/2024 | COT - RSPL - Sewer | Passed | DWV Pipes are connected to the main sewer line and under water pressure test with no leaks. |