Permit Details

Status:
Issued
Type:
Model Building Permit
Address:
9653 E HARKES DR
Apply Date:
04/25/2024
Applicant:
Joshua Swinney
Description:
American Samoa Model Plan La Escalera

Permit Reviews

Permit Number - TC-MDP-0424-00526
Permit Status: Issued
Permit Description: American Samoa Model Plan La Escalera
Start Date Submittal Complete Date Status  
04/26/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 05/01/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0424-00526
Permit Status: Issued
Permit Description: American Samoa Model Plan La Escalera
Total Outstanding Activity Conditions - 5
Date Name
04/25/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
04/30/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
04/30/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
04/30/2024 Post-Tension Inspection Report is required.
04/30/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.

Conditions

Permit Number - TC-MDP-0424-00526
Permit Status: Issued
Permit Description: American Samoa Model Plan La Escalera
Date Description Comments
04/25/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
04/30/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-MDP-0424-00526
Permite Description: American Samoa Model Plan La Escalera
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
10/28/2024 COT - BULD - SWG Clearance N/A Not Applicable
10/28/2024 COT - RSPL - Gas Pressure Test N/A Not Applicable
10/29/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 10/29/24: box fill at garage exterior lighting is exceeding max fill (6 Cubic inches), nail plate required at garage at electrical and kitchen walls and top plates (throughout house first and second floor), circuits installed are not meeting required circuits on approved panel schedule, receptacle missing per plans at laundry room, NM sheathing must extend 1/2" into box at all fixtures ( under stair way kitchen switch ), circuit A-1 at family room is calling for 20Amp breaker (requires 12Awg wiring), wiring size not per plan throughout, mechanical not attached to register upstairs bedroom, all thermostat shall be no higher than 48" o.c above finish floor. STOPPED INSPECTION MORE ITEMS MAY BE ADDED

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0424-00526
Permit Description: American Samoa Model Plan La Escalera
Total Completed Inspections - 9
Date Description Inspector Results Comments
06/17/2024 COT - RSPL - Rough Soil Passed 6/17/24: Underground plumbing is exposed, green tracer wire is installed, system is under water test with no leaks. Okay to shade pipe and backfill trenches.
06/17/2024 COT - RSPL - Yard Water Line Passed 6/17/24: Main water line has been exposed, line is under 40# of air pressure with no leaks. Okay to shade pipe and backfill trench.
06/25/2024 COT - RSEL - Electrical Underground Passed
06/25/2024 COT - RSEL - Grounding/Bonding Passed
06/26/2024 COT - RSBU - Preslab Passed
06/26/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
08/02/2024 COT - RSBU - Exterior Clips/Sheathing Passed All shear walls are properly secured to concrete floor with shear brackets with titan bolts and properly plywood sheathing is properly secured to studs per plan. All interior and exterior wall bottom plates are secured to concrete floor with red heads, masa clips, or titan bolts. Okay to proceed with rough in.
08/02/2024 COT - RSBU - Roof Nailing Passed Roof trusses are properly secured to top plate with nails and H2.5 clips. Plywood sheathing is properly secured to roof trusses with nails and staples. Okay to proceed with rough-in.
10/16/2024 COT - RSPL - Sewer Passed DWV Pipes are connected to the main sewer line and under water pressure test with no leaks.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
PHASE 1 LOT 60 PLOT PLAN_V1.PDF DOCUMENTS VIEW
PHASE 1A LOT 60 SIC-2024-04-25_V1.PDF DOCUMENTS VIEW