Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - TC-MDP-0424-00526
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/29/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 10/29/24: box fill at garage exterior lighting is exceeding max fill (6 Cubic inches), nail plate required at garage at electrical and kitchen walls and top plates (throughout house first and second floor), circuits installed are not meeting required circuits on approved panel schedule, receptacle missing per plans at laundry room, NM sheathing must extend 1/2" into box at all fixtures ( under stair way kitchen switch ), circuit A-1 at family room is calling for 20Amp breaker (requires 12Awg wiring), wiring size not per plan throughout, mechanical not attached to register upstairs bedroom, all thermostat shall be no higher than 48" o.c above finish floor. STOPPED INSPECTION MORE ITEMS MAY BE ADDED | |
11/12/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 11-12-24, box fill at exterior light near garage is exceeding fill-box is rated at 6 cubic inches (box currently has 2 14/2 awg wires), wiring not per approved plans. Provide letter from Austin Electric company and a schematic of layout. These items must be submitted , reviewed, and approved prior to certificate of occupancy can be issued. | |
11/14/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | 11-14-24, listed item from previous inspection were corrected. Okay to proceed at own risk. See previous notes. |