Permit: TC-MDP-0424-00520
Permit Details
Status:
Complete
Type:
Model Building Permit
Address:
9644 E HARKES DR
Address NEW:
9644 E HARKES DR
Apply Date:
06/05/2024
Applicant:
Brianna Quiroz
Description:
SFR 500 Coolidge Model Plan La Escalera
Permit Reviews
Permit Number - TC-MDP-0424-00520
Permit Status: Complete
Permit Description: SFR 500 Coolidge Model Plan La Escalera
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/27/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 04/01/2025 | APPROVED |
| 06/06/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 06/07/2024 | APPROVED |
| 02/25/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/26/2025 | REQUIRES RESUBMIT |
| 03/05/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 03/10/2025 | APPROVED |
Conditions
Permit Number - TC-MDP-0424-00520
Permit Status: Complete
Permit Description: SFR 500 Coolidge Model Plan La Escalera
| Date | Description | Comments |
|---|---|---|
| 06/07/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 06/07/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 06/07/2024 | Post-Tension Inspection Report is required. | |
| 04/25/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 04/25/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
| 02/25/2025 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. | |
| 06/07/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0424-00520
Permite Description: SFR 500 Coolidge Model Plan La Escalera
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/15/2024 | COT - BULD - SWG Clearance | N/A | Not Applicable | 11-15-24, home contains no gas |
| 11/15/2024 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | 11-15-24, residence contains no gas appliances |
| 11/21/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Partial Pass | 11-21-24, with regards to the missing wall receptacle in primary bedroom submit a letter documenting code requirements from Austin electric and a schematic for electrical plan. Okay to proceed at own risk. |
| 11/15/2024 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 11-15-24, roof is weighed down with tiles. I am unable to verify roof nailing. Therefore, provide a letter stating that roof nailing was nailed per approved plans or remove all tiles and reschedule an inspection.Also, pancake box for coach lights at garage are overfilled. Box is rated for 6 cubic inches and it contains 2 14/2 awg wires. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0424-00520
Permit Description: SFR 500 Coolidge Model Plan La Escalera
Total Completed Inspections - 20