| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/26/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 05/01/2024 | APPROVED |
| 05/06/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 05/07/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0424-00491
Permit Status: Inspections complete
Permit Description: SFR RKK35L T21-M0084 REVISION-Structural changes
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 04/17/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
| 04/30/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 04/30/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 04/30/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 04/30/2024 | Post-Tension Inspection Report is required. |
| 04/30/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0424-00491
Permit Status: Inspections complete
Permit Description: SFR RKK35L T21-M0084 REVISION-Structural changes
| Date | Description | Comments |
|---|---|---|
| 04/17/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 04/30/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0424-00491
Permite Description: SFR RKK35L T21-M0084 REVISION-Structural changes
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2024 | ENGR Engineering Final | N/A | Not Applicable |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0424-00491
Permit Description: SFR RKK35L T21-M0084 REVISION-Structural changes
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/16/2024 | COT - RSPL - Backwater Valve | Passed | ||
| 05/16/2024 | COT - RSPL - Yard Water Line | Passed | ||
| 05/16/2024 | COT - RSPL - Rough Soil | Passed | ||
| 05/16/2024 | COT - RSPL - Sewer | Passed | ||
| 05/28/2024 | COT - RSBU - Preslab | Passed | ||
| 05/28/2024 | COT - RSEL - Electrical Underground | Passed | ||
| 06/17/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | All exterior and interior plywood shear walls are properly nailed to studs. Shear wall hold downs are properly secured to concrete floor and nailed off. All bottom plates are secured to the concrete floor with shot pins, masa clips, or red head bolts. Okay to proceed with rough-in of plumbing, electrical, and mechanical. | |
| 06/17/2024 | COT - RSBU - Roof Nailing | Passed | Roof trusses are properly installed and secured to top plate with nails and H2.5 clips. Roof sheathing is properly nailed per plan and code. Okay to proceed with rough-in of mechanical, electrical, and plumbing. | |
| 07/24/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of sheet rock and insulation. | |
| 07/24/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line is under 15 pounds of air pressure and holding without any leaks. Okay to proceed. | |
| 08/13/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 09/17/2024 | BULD - Electrical Clearance | Passed | Clearance for TEP ECO. 9/17/2024 | |
| 09/26/2024 | COT - BULD - SWG Clearance | Passed | PASSED SW GAS CLEARANCE 9/26/2024 | |
| 10/18/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 10/18/2024 | COT - RSME - Mechanical Final | Passed | Construction is complete per plans. Okay to issue Certificate of Occupancy. | |
| 10/18/2024 | RSBU - Building Final | Passed | Construction is complete per plans. Okay to issue Certificate of Occupancy. | |
| 10/18/2024 | COT - RSEL - Outdoor Lighting | Passed | Construction is complete per plans. Okay to issue Certificate of Occupancy. | |
| 10/18/2024 | COT - RSPL - Plumbing Final | Passed | Construction is complete per plans. Okay to issue Certificate of Occupancy. | |
| 10/18/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 10/18/2024 | RSBU - Building Progress | Passed | Construction is complete per plans. Okay to issue Certificate of Occupancy. | |
| 10/18/2024 | COT - RSEL - Electrical Final | Passed | Construction is complete per plans. Okay to issue Certificate of Occupancy. |