Permit: TC-MDP-0423-00839
Permit Details
Apply Date:
04/26/2023
Applicant:
Christi Swenson
Description:
PULT3519-3 T21-M0048 SFR
Permit Reviews
Permit Number - TC-MDP-0423-00839
Permit Status: Inspections complete
Permit Description: PULT3519-3 T21-M0048 SFR
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/09/2023 | ZZZMODEL PERMIT REVIEW RESIDENTIAL v.2 | 05/18/2023 | APPROVED |
04/28/2023 | ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 | 05/01/2023 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-MDP-0423-00839
Permit Status: Inspections complete
Permit Description: PULT3519-3 T21-M0048 SFR
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
04/28/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
04/28/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
04/28/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
05/01/2023 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. |
05/01/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0423-00839
Permit Status: Inspections complete
Permit Description: PULT3519-3 T21-M0048 SFR
Date | Description | Comments |
---|---|---|
04/28/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0423-00839
Permite Description: PULT3519-3 T21-M0048 SFR
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/06/2023 | ENGR Engineering Final | N/A | Not Ready | this site is not ready at this time due to the following two reasons, the drainage swells from the back of the property to the street have not been cut correctly or defined enough that they’re evident and these need to be reworked to ensure that the drainage is done properly. The small retaining wall between this property and the property to the east has some damage block that will need to be re-paired prior to the release of this project or shortly there after. I need to have an on-site meeting with a representative from the builder before consideration of approval for this property can be done. You can call David Roberts at 520-349-7643. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0423-00839
Permit Description: PULT3519-3 T21-M0048 SFR
Total Completed Inspections - 21