Permit: TC-MDP-0326-00154
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
9649 E WYNALDA DR
Address NEW:
9649 E WYNALDA DR
Apply Date:
03/17/2026
Applicant:
Celina Rodriguez
Description:
Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Permit Reviews
Permit Number - TC-MDP-0326-00154
Permit Status: Inspections
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/19/2026 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 04/02/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0326-00154
Permit Status: Inspections
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 03/13/2026 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 03/13/2026 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 03/20/2026 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 03/20/2026 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 03/20/2026 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
| 03/20/2026 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0326-00154
Permit Status: Inspections
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
| Date | Description | Comments |
|---|---|---|
| 03/13/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 03/13/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0326-00154
Permite Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 05/08/2026 Add studs on south wall continuous to foundation for girder truss as marked, add anchor bolt on south wall as marked where Masa clip has one arm up near plate edge, add steel 3" washer plates to SW11 per note L in shear wall schedule sheet S2.1, rear ratio calls for use of hangers instead of pocket beam cutting through shear wall, add 2x4 stiffener to diagonal end bracing exceed 6’ per detail 306 upstairs. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0326-00154
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/14/2026 | COT - RSPL - Yard Water Line | Passed | 04/14/2026 Holding under test. Okay to backfill - shading required. |
|
| 04/14/2026 | COT - RSPL - Sewer | Passed | 04/14/2026 Holding under test to HCS . Okay to backfill - shading required. |
|
| 04/14/2026 | COT - RSPL - Rough Soil | Passed | 04/14/2026 Holding under test. Okay to backfill - shading required. |
|
| 04/20/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 04/20/2026 Approved per plan and reinforcements - ok to pour. |
|
| 04/20/2026 | COT - RSBU - Preslab | Passed | 04/20/2026 Approved per plan and reinforcements - ok to pour. |
|
| 04/20/2026 | COT - RSEL - Electrical Underground | Passed | ||
| 05/08/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 05/13/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 5.13.26 Approved - corrections made |
|
| 06/04/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 06/04/2026 | BULD - Electrical Clearance | Passed |