Permit: TC-MDP-0324-00284
Permit Details
Status:
Complete
Type:
Model Building Permit
Address:
4751 E JULIAN WASH DR
Address NEW:
4751 E JULIAN WASH DR
Apply Date:
06/05/2024
Applicant:
Description:
SFR MERI156021 T21-M0063
Permit Reviews
Permit Number - TC-MDP-0324-00284
Permit Status: Complete
Permit Description: SFR MERI156021 T21-M0063
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/06/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 06/11/2024 | APPROVED |
| 10/09/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/09/2024 | APPROVED |
| 02/13/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/13/2025 | APPROVED |
Conditions
Permit Number - TC-MDP-0324-00284
Permit Status: Complete
Permit Description: SFR MERI156021 T21-M0063
| Date | Description | Comments |
|---|---|---|
| 06/06/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 06/06/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 06/06/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 06/06/2024 | Post-Tension Inspection Report is required. | |
| 03/05/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 03/05/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
| 06/06/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 06/06/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0324-00284
Permite Description: SFR MERI156021 T21-M0063
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/30/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | Gable end bracing not per plan, anchor bolts and shop pins throughout, h25 clips at marked areas, support or replace damaged studs, add stud flush to truss at marked location, shim marked area in garage to account for roof weight, Reinspection required |
| 12/30/2024 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | Gable end bracing not per plan, anchor bolts and shop pins throughout, h25 clips at marked areas, support or replace damaged studs, add stud flush to truss at marked location, shim marked area in garage to account for roof weight, Reinspection required |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0324-00284
Permit Description: SFR MERI156021 T21-M0063
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2024 | COT - RSPL - Yard Water Line | Passed | 12-9-24, backwater valve, underground plumbing, main water line, and sewer connection verified as per approved plans. Okay to backfill. | |
| 12/09/2024 | COT - RSPL - Sewer | Passed | 12-9-24, backwater valve, underground plumbing, main water line, and sewer connection verified as per approved plans. Okay to backfill. | |
| 12/09/2024 | COT - RSPL - Rough Soil | Passed | 12-9-24, backwater valve, underground plumbing, main water line, and sewer connection verified as per approved plans. Okay to backfill. | |
| 12/09/2024 | COT - RSPL - Backwater Valve | Passed | 12-9-24, backwater valve, underground plumbing, main water line, and sewer connection verified as per approved plans. Okay to backfill. | |
| 12/13/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Rebar and hold downs per plans, ok to pour concrete 12/13/24 | |
| 12/13/2024 | COT - RSBU - Preslab | Passed | Rebar and hold downs per plans, ok to pour concrete 12/13/24 | |
| 12/13/2024 | COT - RSEL - Electrical Underground | Passed | Rebar and hold downs per plans, ok to pour concrete 12/13/24 | |
| 12/13/2024 | COT - RSEL - Grounding/Bonding | Passed | Rebar and hold downs per plans, ok to pour concrete 12/13/24 | |
| 01/03/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 1/3/24 corrections made | |
| 01/03/2025 | COT - RSBU - Roof Nailing | Passed | 1/3/24 corrections made | |
| 01/22/2025 | COT - RSPL - Gas Pressure Test | Passed | 1/22/25 pass | |
| 01/23/2025 | BULD - Electrical Clearance | Passed | 1/23/25 pass approval for TEP ECO | |
| 01/23/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 1/23/25 corrections have been made. PASS | |
| 02/06/2025 | COT - RSBU - Interior Shear Bracing | Passed | Passed interior shear 2/6/25 | |
| 03/24/2025 | COT - BULD - SWG Clearance | Passed | Passed SW GAS CLEARANCE 3/24/25 | |
| 04/07/2025 | COT - RSEL - Electrical Final | Passed | ||
| 04/07/2025 | COT - RSEL - Outdoor Lighting | Passed | ||
| 04/07/2025 | ENGR Engineering Final | Passed | CO READY | |
| 04/07/2025 | RSBU - Building Progress | Passed | ||
| 04/09/2025 | COT - RSPL - Plumbing Final | Passed | ||
| 04/10/2025 | COT - RSME - Mechanical Final | Passed | 4/10/2025 corrections were made. | |
| 04/10/2025 | RSBU - Building Final | Passed | 4/10/2025 corrections were made. |