Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0323-00757
Permit Details
Apply Date:
10/19/2023
Applicant:
Russ Salmon
Description:
SFR LENNLE4001 T22-M0045
Permit Reviews
Permit Number - TC-MDP-0323-00757
Permit Status: Inspections complete
Permit Description: SFR LENNLE4001 T22-M0045
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/19/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 10/23/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0323-00757
Permit Status: Inspections complete
Permit Description: SFR LENNLE4001 T22-M0045
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
03/16/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
07/14/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
10/19/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
10/19/2023 | Post-Installed Anchor Inspection Report is required. |
10/19/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0323-00757
Permit Status: Inspections complete
Permit Description: SFR LENNLE4001 T22-M0045
Date | Description | Comments |
---|---|---|
07/14/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0323-00757
Permite Description: SFR LENNLE4001 T22-M0045
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2023 | COT - RSBU - Exterior Clips/Sheathing | N/A | Re-inspection required | Missing anchor bolt at front of house, beam to post connections at front porch not per S5.1 #6, back porch post to beam not installed per detail S5.1 #6 and beam must be supported by 2-2x6 stud at each end per plans, bed. 2 window missing second king stud at each end, add shot pins to sole plate at master bathroom, truss A05 missing lateral bracing. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0323-00757
Permit Description: SFR LENNLE4001 T22-M0045
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/22/2023 | COT - RSPL - Rough Soil | Passed | ||
11/22/2023 | COT - RSPL - Sewer | Passed | ||
11/22/2023 | COT - RSPL - Yard Water Line | Passed | ||
12/01/2023 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
12/01/2023 | COT - RSBU - Preslab | Passed | ||
12/01/2023 | COT - RSEL - Electrical Underground | Passed | ||
12/01/2023 | COT - RSEL - Grounding/Bonding | Passed | ||
12/21/2023 | COT - RSBU - Roof Nailing | Passed | ||
01/10/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
03/11/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall. | |
03/11/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line is holding 15# of compressed air with no leaks in piping. | |
03/11/2024 | RSBU - Building Progress | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall. | |
03/18/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
04/09/2024 | BULD - Electrical Clearance | Passed | ||
05/14/2024 | COT - BULD - SWG Clearance | Passed | ||
06/24/2024 | COT - RSEL - Electrical Final | Passed | ||
06/24/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
06/24/2024 | COT - RSME - Mechanical Final | Passed | ||
06/24/2024 | COT - RSPL - Plumbing Final | Passed | ||
06/24/2024 | ENGR Engineering Final | Passed | ||
06/24/2024 | RSBU - Building Final | Passed |