Permit: TC-MDP-0323-00757

Parcel: 141434710

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
01/05/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required bed. 2 window missing second king stud at each end, truss A05 missing lateral bracing.
01/10/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
12/21/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Missing anchor bolt at front of house, beam to post connections at front porch not per S5.1 #6, back porch post to beam not installed per detail S5.1 #6 and beam must be supported by 2-2x6 stud at each end per plans, bed. 2 window missing second king stud at each end, add shot pins to sole plate at master bathroom, truss A05 missing lateral bracing.