La Estancia T913 renewal submittal - no changes formerly T19-M0025

Permit Reviews

Permit Number - TC-MDP-0323-00670
Permit Status: Complete
Permit Description: La Estancia T913 renewal submittal - no changes formerly T19-M0025
Start Date Submittal Complete Date Status  
03/08/2023 RESIDENTIAL NEW DWELLING v.1 03/10/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0323-00670
Permit Status: Complete
Permit Description: La Estancia T913 renewal submittal - no changes formerly T19-M0025
Total Outstanding Activity Conditions - 5
Date Name
03/10/2023 Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents.
03/10/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
03/10/2023 Post-Installed Anchor Inspection Report is required.
03/10/2023 Post-Tension Inspection Report is required.
03/10/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-0323-00670
Permite Description: La Estancia T913 renewal submittal - no changes formerly T19-M0025
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
06/26/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 6-15-23: 1-B vent for water heater needs 1" clearance from combustibles. 2-No test on gas piping. 3-Seal all fire blocking. 4-Staples missing for electrical. 5-apex piping is less than 12" from recessed cans; move or verify IC rating of cans.
Inspection stopped; walk for compliance before rescheduling inspection.

6/26/23: seal penetrations through top and bottom plates at second floor, fireblock duct work going through ceiling, staple missing on romex at laundry, dwv not under test, seal penetrations at top plates in chases under stairs.
06/15/2023 COT - RSME - Mechanical Final N/A Not Ready

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0323-00670
Permit Description: La Estancia T913 renewal submittal - no changes formerly T19-M0025
Total Completed Inspections - 19

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-LA ESTANCIA II LOT 690 SITE PLOT 030823_V1.PDF DOCUMENTS VIEW
LA ESTANCIA II LOT 690 SIC 030823-2023-03-08_V1.PDF DOCUMENTS VIEW