Permit: TC-MDP-0224-00255
Permit Details
Apply Date:
02/27/2024
Applicant:
Paula Hinman
Description:
Blackhawk T609 - Lawson
Permit Reviews
Permit Number - TC-MDP-0224-00255
Permit Status: Inspections complete
Permit Description: Blackhawk T609 - Lawson
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/12/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/14/2024 | APPROVED |
02/29/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 03/11/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0224-00255
Permit Status: Inspections complete
Permit Description: Blackhawk T609 - Lawson
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/27/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-0224-00255
Permit Status: Inspections complete
Permit Description: Blackhawk T609 - Lawson
Date | Description | Comments |
---|---|---|
03/09/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
03/09/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
03/09/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
02/27/2024 | Post-Tension Inspection Report is required. | |
02/27/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
12/22/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
12/22/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
03/09/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0224-00255
Permite Description: Blackhawk T609 - Lawson
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2024 | COT - RSBU - Exterior Clips/Sheathing | N/A | Partial Pass | Missing HUC410 hangers for beams in garage, front of garage missing anchor bolts, right side of garage missing second stud for post above per plans. Add blocking between floors to allow continuous Los transfer from second floor to first floor, front porch beams must be supported by 2-2x4 studs at each end, missing second 2x6 stud for GT by bottom stairs landing, missing anchor bolts at shear walls throughout, missing 2-2x4 studs for post above at back of house per plans, missing anchor bolt back left and right corners of house, missed STHD hold down. Replace with proper substitute., missing anchor bolts throughout, missing 2-2x6 BF studs for GT at second floor per plans, missing second king stud at each end of master window. Failure to read plans and QC walk for future inspections will result in failed inspections after three items found. Front porch beams must be supported by 2-2x4 studs at each end, missing second 2x6 stud for GT by bottom stairs landing, missed STHD hold down. Replace with proper substitute, missing second king stud at each end of master window. House has been lathed and proceeded to intermediate without passing exterior clips and sheathing. Remove lath at front porch columns and all hold down locations to conduct proper re-inspection. Re-inspection required with fee. Front porch beams must be supported by 2-2x4 studs at each end, missing second 2x6 stud for GT by bottom stairs landing, missed STHD hold down. Replace with proper substitute, missing second king stud at each end of master window. House has been lathed and proceeded to intermediate without passing exterior clips and sheathing. Remove lath at front porch columns and all hold down locations to conduct proper re-inspection. 6/21/24: ok to proceed with lath, missing king studs at master bedroom window. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0224-00255
Permit Description: Blackhawk T609 - Lawson
Total Completed Inspections - 22