Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 140443020


Addresses:

6033 E CAMPOLINA TR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0224-00255

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
05/14/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing HUC410 hangers for beams in garage, front of garage missing anchor bolts, right side of garage missing second stud for post above per plans. Add blocking between floors to allow continuous Los transfer from second floor to first floor, front porch beams must be supported by 2-2x4 studs at each end, missing second 2x6 stud for GT by bottom stairs landing, missing anchor bolts at shear walls throughout, missing 2-2x4 studs for post above at back of house per plans, missing anchor bolt back left and right corners of house, missed STHD hold down. Replace with proper substitute., missing anchor bolts throughout, missing 2-2x6 BF studs for GT at second floor per plans, missing second king stud at each end of master window. Failure to read plans and QC walk for future inspections will result in failed inspections after three items found.
06/04/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required (with fee) Front porch beams must be supported by 2-2x4 studs at each end, missing second 2x6 stud for GT by bottom stairs landing, missed STHD hold down. Replace with proper substitute, missing second king stud at each end of master window. House has been lathed and proceeded to intermediate without passing exterior clips and sheathing. Remove lath at front porch columns and all hold down locations to conduct proper re-inspection. Re-inspection required with fee.
06/13/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Front porch beams must be supported by 2-2x4 studs at each end, missing second 2x6 stud for GT by bottom stairs landing, missed STHD hold down. Replace with proper substitute, missing second king stud at each end of master window. House has been lathed and proceeded to intermediate without passing exterior clips and sheathing. Remove lath at front porch columns and all hold down locations to conduct proper re-inspection.
06/21/2024 COT - RSBU - Exterior Clips/Sheathing  Partial Pass Missing HUC410 hangers for beams in garage, front of garage missing anchor bolts, right side of garage missing second stud for post above per plans. Add blocking between floors to allow continuous Los transfer from second floor to first floor, front porch beams must be supported by 2-2x4 studs at each end, missing second 2x6 stud for GT by bottom stairs landing, missing anchor bolts at shear walls throughout, missing 2-2x4 studs for post above at back of house per plans, missing anchor bolt back left and right corners of house, missed STHD hold down. Replace with proper substitute., missing anchor bolts throughout, missing 2-2x6 BF studs for GT at second floor per plans, missing second king stud at each end of master window. Failure to read plans and QC walk for future inspections will result in failed inspections after three items found.

Front porch beams must be supported by 2-2x4 studs at each end, missing second 2x6 stud for GT by bottom stairs landing, missed STHD hold down. Replace with proper substitute, missing second king stud at each end of master window. House has been lathed and proceeded to intermediate without passing exterior clips and sheathing. Remove lath at front porch columns and all hold down locations to conduct proper re-inspection. Re-inspection required with fee.

Front porch beams must be supported by 2-2x4 studs at each end, missing second 2x6 stud for GT by bottom stairs landing, missed STHD hold down. Replace with proper substitute, missing second king stud at each end of master window. House has been lathed and proceeded to intermediate without passing exterior clips and sheathing. Remove lath at front porch columns and all hold down locations to conduct proper re-inspection.

6/21/24: ok to proceed with lath, missing king studs at master bedroom window.
06/25/2024 COT - RSBU - Exterior Clips/Sheathing  Passed Corrections were made. 6/25/2024