Permit: TC-MDP-0224-00228
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
6054 E FALCONRY TR
Address NEW:
6054 E FALCONRY TR
Apply Date:
02/21/2024
Applicant:
Helen Ormsby
Description:
Blackhawk H30D Model Plan
Permit Reviews
Permit Number - TC-MDP-0224-00228
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/26/2024 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 02/29/2024 | APPROVED |
| 06/11/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 06/11/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0224-00228
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 02/12/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
| 02/20/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-0224-00228
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
| Date | Description | Comments |
|---|---|---|
| 02/29/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 02/29/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 10/03/2023 | Post-Tension Inspection Report is required. | |
| 02/12/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 02/29/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 09/07/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0224-00228
Permite Description: Blackhawk H30D Model Plan
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/29/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 4/29/24: T-ply at shear walls not fastened per schedule, Anchor bolts missing 12" from sill plate edge, more than 3 continuous M.A.S.A clips with one leg up throughout (add anchor bolts to meet proper requirements), holdown at garage on north east corner not per plans (plans call for HTT5-KT/HTT45-KT). |
| 06/03/2024 | COT - RSBU - Interior Shear Bracing | N/A | Re-inspection required | 6/3/24: fasteners shall not be closer than 3/8" from edges and ends, fasteners over spanned at ceiling. Fasteners missing throughout at bottom plates. |
| 06/03/2024 | COT - BULD - SWG Clearance | N/A | Re-inspection required | 6/3/24: fasteners shall not be closer than 3/8" from edges and ends, fasteners over spanned at ceiling. Fasteners missing throughout at bottom plates. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0224-00228
Permit Description: Blackhawk H30D Model Plan
Total Completed Inspections - 21