Permit Reviews
Permit Number - TC-MDP-0224-00228
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/26/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 02/29/2024 | APPROVED |
06/11/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 06/11/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0224-00228
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
02/12/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
02/20/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-0224-00228
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
Date | Description | Comments |
---|---|---|
02/29/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
02/29/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
10/03/2023 | Post-Tension Inspection Report is required. | |
02/12/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
02/29/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
09/07/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0224-00228
Permite Description: Blackhawk H30D Model Plan
Total Outstanding Inspections - 3
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/29/2024 | COT - RSBU - Exterior Clips/Sheathing | N/A | Re-inspection required | 4/29/24: T-ply at shear walls not fastened per schedule, Anchor bolts missing 12" from sill plate edge, more than 3 continuous M.A.S.A clips with one leg up throughout (add anchor bolts to meet proper requirements), holdown at garage on north east corner not per plans (plans call for HTT5-KT/HTT45-KT). |
06/03/2024 | COT - RSBU - Interior Shear Bracing | N/A | Re-inspection required | 6/3/24: fasteners shall not be closer than 3/8" from edges and ends, fasteners over spanned at ceiling. Fasteners missing throughout at bottom plates. |
06/03/2024 | COT - BULD - SWG Clearance | N/A | Re-inspection required | 6/3/24: fasteners shall not be closer than 3/8" from edges and ends, fasteners over spanned at ceiling. Fasteners missing throughout at bottom plates. |
Completed Inspections