Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Apply Date:
02/21/2024
Applicant:
Kelly Rayman
Description:
Blackhawk H30D Model Plan

Permit Reviews

Permit Number - TC-MDP-0224-00228
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
Start Date Submittal Complete Date Status  
02/26/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 02/29/2024 APPROVED Review Details
06/11/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 06/11/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0224-00228
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
Total Outstanding Activity Conditions - 2
Date Name
02/12/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
02/20/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.

Conditions

Permit Number - TC-MDP-0224-00228
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
Date Description Comments
02/29/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
02/29/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
10/03/2023 Post-Tension Inspection Report is required.
02/12/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
02/29/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
09/07/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0224-00228
Permite Description: Blackhawk H30D Model Plan
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
04/29/2024 COT - RSBU - Exterior Clips/Sheathing N/A Re-inspection required 4/29/24: T-ply at shear walls not fastened per schedule, Anchor bolts missing 12" from sill plate edge, more than 3 continuous M.A.S.A clips with one leg up throughout (add anchor bolts to meet proper requirements), holdown at garage on north east corner not per plans (plans call for HTT5-KT/HTT45-KT).
06/03/2024 COT - RSBU - Interior Shear Bracing N/A Re-inspection required 6/3/24: fasteners shall not be closer than 3/8" from edges and ends, fasteners over spanned at ceiling. Fasteners missing throughout at bottom plates.
06/03/2024 COT - BULD - SWG Clearance N/A Re-inspection required 6/3/24: fasteners shall not be closer than 3/8" from edges and ends, fasteners over spanned at ceiling. Fasteners missing throughout at bottom plates.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0224-00228
Permit Description: Blackhawk H30D Model Plan
Total Completed Inspections - 21

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW