Permit: TC-MDP-0224-00224
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
10064 S ARNOLD RANCH CT
Address NEW:
10064 S ARNOLD RANCH CT
Apply Date:
07/08/2024
Applicant:
Ben Smith
Description:
SFR RKK35O T22-M0068 Revision- Builder updates Structural and post tension
Permit Reviews
Permit Number - TC-MDP-0224-00224
Permit Status: Inspections complete
Permit Description: SFR RKK35O T22-M0068 Revision- Builder updates Structural and post tension
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/12/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.4 | 08/16/2024 | REQUIRES RESUBMIT |
| 08/28/2024 | RESTAMP - RESIDENTIAL v.1 | 08/28/2024 | REQUIRES RESUBMIT |
| 08/23/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.5 | 08/28/2024 | APPROVED |
| 08/08/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.3 | 08/08/2024 | REQUIRES RESUBMIT |
| 07/11/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.2 | 07/12/2024 | REQUIRES RESUBMIT |
| 08/29/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 09/03/2024 | APPROVED |
| 07/08/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 07/09/2024 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-MDP-0224-00224
Permit Status: Inspections complete
Permit Description: SFR RKK35O T22-M0068 Revision- Builder updates Structural and post tension
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 02/20/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
| 07/09/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 07/09/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 07/09/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 07/09/2024 | Post-Tension Inspection Report is required. |
| 07/09/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0224-00224
Permit Status: Inspections complete
Permit Description: SFR RKK35O T22-M0068 Revision- Builder updates Structural and post tension
| Date | Description | Comments |
|---|---|---|
| 02/20/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 07/09/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0224-00224
Permite Description: SFR RKK35O T22-M0068 Revision- Builder updates Structural and post tension
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 10-24-24, Add nails throughout second floor sill plate to decking,add bracing to h03 truss, add anchor bolt to Southwest patio column, provide engineer fix for chord to gusset plate in first floor hallway |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0224-00224
Permit Description: SFR RKK35O T22-M0068 Revision- Builder updates Structural and post tension
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/13/2024 | COT - RSPL - Yard Water Line | Passed | Main water supply line is connected to city water with a meter installed. Water line is under street pressure with no leaks. Okay to shade pipe and backfill trench. | |
| 09/13/2024 | COT - RSPL - Sewer | Passed | Underground plumbing is connected to backwater valve and main sewer line, entire system is under a water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 09/13/2024 | COT - RSPL - Rough Soil | Passed | Underground plumbing is connected to backwater valve and main sewer line, entire system is under a water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 09/13/2024 | COT - RSPL - Backwater Valve | Passed | Underground plumbing is connected to backwater valve and main sewer line, entire system is under a water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 09/26/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 09/26/2024 | COT - RSBU - Preslab | Passed | ||
| 09/26/2024 | COT - RSEL - Electrical Underground | Passed | ||
| 09/26/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 10/24/2024 | COT - RSBU - Roof Nailing | Passed | 10-24-24, roof nailing approved. | |
| 11/25/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall. | |
| 11/25/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 11/25/24: Engineering letter provided for truss repair. Okay to proceed with other work. | |
| 11/25/2024 | BULD - Electrical Clearance | Passed | ECO CLEARANCE ISSUED. | |
| 11/25/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line is under a 15 psi air pressure test with no leaks. Okay to proceed with other work. | |
| 12/09/2024 | COT - RSBU - Interior Shear Bracing | Passed | 12-9-24, shear wall bracing inspection approved. Okay to tape & texture drywall. | |
| 02/06/2025 | COT - BULD - SWG Clearance | Passed | Passed SWG GAS CLEARANCE 2/6/24 | |
| 02/25/2025 | RSBU - Building Progress | Passed | ||
| 02/25/2025 | COT - RSME - Mechanical Final | Passed | ||
| 02/25/2025 | ENGR Engineering Final | Passed | CO Ready Again if tree stakes are to be used they need to be finished |
|
| 02/25/2025 | COT - RSEL - Outdoor Lighting | Passed | ||
| 02/25/2025 | COT - RSPL - Plumbing Final | Passed | ||
| 02/26/2025 | RSBU - Building Final | Passed | 26 FEB 25 Pass, all corrections have been made. |
|
| 02/26/2025 | COT - RSEL - Electrical Final | Passed | 26 FEB 25 Pass, all corrections have been made. |