Permit: TC-MDP-0223-00591
Permit Details
Apply Date:
06/29/2023
Applicant:
Daria Hopkins
Description:
SFR 235.2960 T21-M0055
Permit Reviews
Permit Number - TC-MDP-0223-00591
Permit Status: Complete
Permit Description: SFR 235.2960 T21-M0055
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/06/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/07/2024 | APPROVED |
06/30/2023 | RESIDENTIAL NEW DWELLING v.1 | 07/05/2023 | APPROVED |
Conditions
Permit Number - TC-MDP-0223-00591
Permit Status: Complete
Permit Description: SFR 235.2960 T21-M0055
Date | Description | Comments |
---|---|---|
06/30/2023 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. | |
02/07/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
06/30/2023 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. | |
06/30/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
02/07/2024 | Post-Tension Inspection Report is required. | |
06/30/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
06/30/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
06/30/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0223-00591
Permite Description: SFR 235.2960 T21-M0055
Total Outstanding Inspections - 7
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/05/2023 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 9/5/23: 2 STHD 8 at shearwalls are supposed to be STHD 10. Verify all STHD size and location |
09/05/2023 | COT - RSBU - Preslab | N/A | Re-inspection required | 9/5/23: 2 STHD 8 at shearwalls are supposed to be STHD 10. Verify all STHD size and location |
09/05/2023 | COT - RSEL - Electrical Underground | N/A | Re-inspection required | |
09/05/2023 | COT - RSEL - Grounding/Bonding | N/A | Re-inspection required | 9/5/23: 2 STHD 8 at shearwalls are supposed to be STHD 10. Verify all STHD size and location |
11/07/2023 | BULD - Electrical Clearance | N/A | Re-inspection required | Secure gas lines throughout, add more nails to nail plate for range vent, leak at first floor ceiling by bedroom entrance, properly support duct registers, add bang plate at top plate of first floor bedroom at plumbing, add correctly sized trimmer stud at right side of powder room door way under stairs, fix penetration at vapor barrier between ballon framed studs right side of front window and left side of front window, support 4-gang box at loft, missing clean outs at second floor, properly fire block horizontal chase at front house second floor pop out, over spanned studs at wall between bed. 2 and bed. 3, fractured top plate and stud at wall between bedroom 3 and hallway, support copper piping for bathtub and shower, supporting in second floor bathroom, open chases at back side of house behind shower, missing temp. gfci receptacle at electrical service. |
11/07/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | Secure gas lines throughout, add more nails to nail plate for range vent, leak at first floor ceiling by bedroom entrance, properly support duct registers, add bang plate at top plate of first floor bedroom at plumbing, add correctly sized trimmer stud at right side of powder room door way under stairs, fix penetration at vapor barrier between ballon framed studs right side of front window and left side of front window, support 4-gang box at loft, missing clean outs at second floor, properly fire block horizontal chase at front house second floor pop out, over spanned studs at wall between bed. 2 and bed. 3, fractured top plate and stud at wall between bedroom 3 and hallway, support copper piping for bathtub and shower, supporting in second floor bathroom, open chases at back side of house behind shower, missing temp. gfci receptacle at electrical service. |
02/20/2024 | ENGR Engineering Final | N/A | Not Ready | No, such address can’t find it |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0223-00591
Permit Description: SFR 235.2960 T21-M0055
Total Completed Inspections - 22