Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-MDP-0223-00591

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
11/07/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Secure gas lines throughout, add more nails to nail plate for range vent, leak at first floor ceiling by bedroom entrance, properly support duct registers, add bang plate at top plate of first floor bedroom at plumbing, add correctly sized trimmer stud at right side of powder room door way under stairs, fix penetration at vapor barrier between ballon framed studs right side of front window and left side of front window, support 4-gang box at loft, missing clean outs at second floor, properly fire block horizontal chase at front house second floor pop out, over spanned studs at wall between bed. 2 and bed. 3, fractured top plate and stud at wall between bedroom 3 and hallway, support copper piping for bathtub and shower, supporting in second floor bathroom, open chases at back side of house behind shower, missing temp. gfci receptacle at electrical service.
11/13/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed