Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0223-00416
Permit Details
Apply Date:
01/05/2024
Applicant:
Daria Hopkins
Description:
SFR MER1301460 T21-M0072
Permit Reviews
Permit Number - TC-MDP-0223-00416
Permit Status: Complete
Permit Description: SFR MER1301460 T21-M0072
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/16/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 05/17/2024 | APPROVED |
01/05/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 01/11/2024 | APPROVED |
09/26/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/26/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0223-00416
Permit Status: Complete
Permit Description: SFR MER1301460 T21-M0072
Date | Description | Comments |
---|---|---|
01/05/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
01/05/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
01/05/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
01/09/2024 | Post-Tension Inspection Report is required. | |
01/05/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
05/17/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
01/05/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
05/17/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
05/17/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
01/09/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0223-00416
Permite Description: SFR MER1301460 T21-M0072
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/12/2024 | COT - RSEL - Electrical Final | N/A | Re-inspection required | Wrong amperage on A/C Unit. 50 amp installed label on unit says 40 amp maximum. |
08/12/2024 | COT - RSME - Mechanical Final | N/A | Re-inspection required | Wrong amperage on A/C Unit. 50 amp installed label on unit says 40 amp maximum. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0223-00416
Permit Description: SFR MER1301460 T21-M0072
Total Completed Inspections - 19
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/02/2024 | COT - RSPL - Rough Soil | Passed | ||
04/02/2024 | COT - RSPL - Sewer | Passed | ||
04/02/2024 | COT - RSPL - Yard Water Line | Passed | ||
04/09/2024 | COT - RSBU - Preslab | Passed | ||
04/09/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
04/09/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
04/09/2024 | COT - RSEL - Electrical Underground | Passed | ||
04/29/2024 | COT - RSBU - Roof Nailing | Passed | Trusses are properly secured to top plate with H2.5 clips and plywood sheathing is installed and secured to trusses per nail pattern on plans. | |
04/29/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | All walls are properly secured to concrete floor, all shear walls are properly bolted down to floor and plywood sheathing is properly secured to studs per plan requirements, and all masa clips are properly secured to bottom plate. | |
05/23/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
05/23/2024 | BULD - Electrical Clearance | Passed | TEP ECO | |
05/23/2024 | RSBU - Building Progress | Passed | ||
05/28/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
06/21/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
07/29/2024 | COT - BULD - SWG Clearance | Passed | Gas valves are installed on each gas appliance location. Okay to install meter and turn on gas. | |
08/12/2024 | COT - RSEL - Outdoor Lighting | Passed | Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled with AFCI & GFCI breakers installed as required. Exterior lights are installed per plan requirements. Okay to issue Certificate of Occupancy for this permit. | |
08/12/2024 | RSBU - Building Final | Passed | Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled with AFCI & GFCI breakers installed as required. Exterior lights are installed per plan requirements. Okay to issue Certificate of Occupancy for this permit. | |
08/12/2024 | ENGR Engineering Final | Passed | ||
08/12/2024 | COT - RSPL - Plumbing Final | Passed | Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled with AFCI & GFCI breakers installed as required. Exterior lights are installed per plan requirements. Okay to issue Certificate of Occupancy for this permit. |