Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0124-00138
Permit Details
Apply Date:
06/26/2024
Applicant:
Craig Morczynski
Description:
SFR LENNLE4005 T22-M0049
Permit Reviews
Permit Number - TC-MDP-0124-00138
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/27/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 06/27/2024 | REQUIRES RESUBMIT |
07/25/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.2 | 08/05/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0124-00138
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
01/24/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
07/13/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
08/02/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
08/02/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
08/02/2024 | Post-Tension Inspection Report is required. |
08/02/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0124-00138
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Date | Description | Comments |
---|---|---|
01/24/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
07/13/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-MDP-0124-00138
Permite Description: SFR LENNLE4005 T22-M0049
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/11/2024 | COT - RSBU - Preslab | N/A | Re-inspection required | Same as before 9/11/24 |
10/02/2024 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 10/2/24: Anchor bolt spacing not per plan throughout, MASA clips not properly fastened, Multiple MASA clips with 1 leg up on a set of 3, King/Trimmer stud at SGD not per plan, porch columns must be properly secured, shear-walls not fastened per schedule at first fl floor and second floor, shear-walls wall sill plate attachments not per schedule at second floor, balloon framing requires blocking at 10', rsp4 at second floor not per plan, roof sheathing not properly fastened, great room opening studs must be properly supported on sill plate. hanger at stairs compromised. |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Scheduled | ||
COT - RSPL - Gas Pressure Test | N/A | Scheduled |
Completed Inspections
Permit Status: Issued
Permit Number: TC-MDP-0124-00138
Permit Description: SFR LENNLE4005 T22-M0049
Total Completed Inspections - 9
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2024 | COT - RSPL - Rough Soil | Passed | Okay to backfill. Shading required. 8/28/2024 | |
08/28/2024 | COT - RSPL - Sewer | Passed | Okay to backfill. Shading required. 8/28/2024 | |
08/28/2024 | COT - RSPL - Yard Water Line | Passed | Okay to backfill. Shading required. 8/28/2024 | |
09/09/2024 | COT - RSEL - Electrical Underground | Passed | ||
09/09/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
09/13/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Approved. Okay for concrete placement. 9/13/2024 | |
09/13/2024 | COT - RSBU - Preslab | Passed | Approved. Okay for concrete placement. 9/13/2024 | |
10/11/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | corrections were made. 10/11/2024 | |
10/11/2024 | COT - RSBU - Roof Nailing | Passed | corrections were made. 10/11/2024 |
Scheduled Inspections
Scheduled Inspections - TC-MDP-0124-00138
Status: Issued
Description: SFR LENNLE4005 T22-M0049
Scheduled Date | Description | Entered By | Entered Date |
---|---|---|---|
12/23/2024 | COT - RSPL - Gas Pressure Test | Scheduled | |
12/23/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.