Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Apply Date:
06/26/2024
Applicant:
Craig Morczynski
Description:
SFR LENNLE4005 T22-M0049

Permit Reviews

Permit Number - TC-MDP-0124-00138
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Start Date Submittal Complete Date Status  
06/27/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 06/27/2024 REQUIRES RESUBMIT Review Details
07/25/2024 SITE FROM MODEL PERMIT - PRODUCTION v.2 08/05/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0124-00138
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Total Outstanding Activity Conditions - 6
Date Name
01/24/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
07/13/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
08/02/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
08/02/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
08/02/2024 Post-Tension Inspection Report is required.
08/02/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.

Conditions

Permit Number - TC-MDP-0124-00138
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Date Description Comments
01/24/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/13/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-MDP-0124-00138
Permite Description: SFR LENNLE4005 T22-M0049
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
09/11/2024 COT - RSBU - Preslab N/A Re-inspection required Same as before 9/11/24
10/02/2024 COT - RSBU - Roof Nailing N/A Re-inspection required 10/2/24: Anchor bolt spacing not per plan throughout, MASA clips not properly fastened, Multiple MASA clips with 1 leg up on a set of 3, King/Trimmer stud at SGD not per plan, porch columns must be properly secured, shear-walls not fastened per schedule at first fl floor and second floor, shear-walls wall sill plate attachments not per schedule at second floor, balloon framing requires blocking at 10', rsp4 at second floor not per plan, roof sheathing not properly fastened, great room opening studs must be properly supported on sill plate. hanger at stairs compromised.
10/07/2024 COT - RSBU - Exterior Clips/Sheathing N/A Re-inspection required great room opening studs must be properly supported on sill plate. Missing anchor bolts at all marked areas. rsp4 at second floor not per plan. 10/7/2024

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0124-00138
Permit Description: SFR LENNLE4005 T22-M0049
Total Completed Inspections - 7
Date Description Inspector Results Comments
08/28/2024 COT - RSPL - Rough Soil Passed Okay to backfill. Shading required. 8/28/2024
08/28/2024 COT - RSPL - Sewer Passed Okay to backfill. Shading required. 8/28/2024
08/28/2024 COT - RSPL - Yard Water Line Passed Okay to backfill. Shading required. 8/28/2024
09/09/2024 COT - RSEL - Electrical Underground Passed
09/09/2024 COT - RSEL - Grounding/Bonding Passed
09/13/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Approved. Okay for concrete placement. 9/13/2024
09/13/2024 COT - RSBU - Preslab Passed Approved. Okay for concrete placement. 9/13/2024

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COT LENNAR LETTERHEAD_V1.PDF DOCUMENTS VIEW
LE II 6 PLOT_V2.PDF DOCUMENTS VIEW
LE II 6 SIC-2024-07-24_V2.PDF DOCUMENTS VIEW