Permit Reviews
Permit Number - TC-MDP-0124-00100
Permit Status: Inspections complete
Permit Description: SFR BT1262-130 T22-M0016
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/29/2025 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 02/05/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0124-00100
Permit Status: Inspections complete
Permit Description: SFR BT1262-130 T22-M0016
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 01/17/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
| 01/29/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 01/29/2025 | Post-Installed Anchor Inspection Report is required. |
| 01/29/2025 | Post-Tension Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0124-00100
Permit Status: Inspections complete
Permit Description: SFR BT1262-130 T22-M0016
| Date | Description | Comments |
|---|---|---|
| 01/29/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 01/17/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0124-00100
Permite Description: SFR BT1262-130 T22-M0016
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/14/2025 | COT - RSEL - Grounding/Bonding | N/A | Partial Pass | Okay to pour concrete. Forms are set, post tension cabling is evenly spaced, shear wall and masa clips are attached to form where required, underground electrical is installed for kitchen island, all underground plumbing is properly wrapped, and rebar is installed for Ufer ground. |
| 02/28/2025 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 28 FEB 25 1. Shot pins are missing in interiors walls, within 6" of every edge. 2. Truss A1E is missing lateral bracing, just south of first brace. |
| 02/26/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 2/26/25: RSP4 at south wall near entry must be properly fastened, At sill plates greater than 12" (2) Anchor bolts required, Anchor bolt required 12" from edge of sill plate, At shear wall 11 and greater 3"x3" washer plates required. STOPPED INSPECTION MORE ITEMS MAY BE ADDED |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0124-00100
Permit Description: SFR BT1262-130 T22-M0016
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/11/2025 | COT - RSPL - Rough Soil | Passed | Passed 2/11/25 ok to backfill | |
| 02/11/2025 | COT - RSPL - Sewer | Passed | Passed 2/11/25 ok to backfill | |
| 02/11/2025 | COT - RSPL - Yard Water Line | Passed | Passed 2/11/25 ok to backfill | |
| 02/14/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Okay to pour concrete. Forms are set, post tension cabling is evenly spaced, shear wall and masa clips are attached to form where required, underground electrical is installed for kitchen island, all underground plumbing is properly wrapped, and rebar is installed for Ufer ground. | |
| 02/14/2025 | COT - RSBU - Preslab | Passed | Okay to pour concrete. Forms are set, post tension cabling is evenly spaced, shear wall and masa clips are attached to form where required, underground electrical is installed for kitchen island, all underground plumbing is properly wrapped, and rebar is installed for Ufer ground. | |
| 02/14/2025 | COT - RSEL - Electrical Underground | Passed | Okay to pour concrete. Forms are set, post tension cabling is evenly spaced, shear wall and masa clips are attached to form where required, underground electrical is installed for kitchen island, all underground plumbing is properly wrapped, and rebar is installed for Ufer ground. | |
| 02/28/2025 | COT - RSEL - Grounding/Bonding | Passed | 28 FEB 25 Pass |
|
| 03/03/2025 | COT - RSBU - Roof Nailing | Passed | 3 March 25 Pass |
|
| 03/03/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 3 MAR 25 ALL CORRECTIONS HAVE BEEN MADE. |
|
| 03/10/2025 | BULD - Electrical Clearance | Passed | 10 MAR 25 TEP CLEARANCE: ECO |
|
| 03/20/2025 | COT - RSPL - Gas Pressure Test | Passed | ||
| 03/25/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 3/25/25 corrections made | |
| 04/07/2025 | COT - RSBU - Interior Shear Bracing | Passed | Passed 4/7/25 ok to tape | |
| 05/12/2025 | COT - BULD - SWG Clearance | Passed | 5/12/25 SOUTHWEST GAS CLEARANCE: SWG |
|
| 05/19/2025 | COT - RSEL - Electrical Final | Passed | passed final 5/19/25 | |
| 05/19/2025 | COT - RSEL - Outdoor Lighting | Passed | passed final 5/19/25 | |
| 05/19/2025 | COT - RSME - Mechanical Final | Passed | passed final 5/19/25 | |
| 05/19/2025 | COT - RSPL - Plumbing Final | Passed | passed final 5/19/25 | |
| 05/19/2025 | RSBU - Building Final | Passed | passed final 5/19/25 | |
| 05/19/2025 | RSBU - Building Progress | Passed | passed final 5/19/25 | |
| 05/22/2025 | ENGR Engineering Final | Passed | Flatwork is complete, site is in accordance with approved plans. CofO ready. |