Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 2/26/25: RSP4 at south wall near entry must be properly fastened, At sill plates greater than 12" (2) Anchor bolts required, Anchor bolt required 12" from edge of sill plate, At shear wall 11 and greater 3"x3" washer plates required. STOPPED INSPECTION MORE ITEMS MAY BE ADDED | ||
| 02/28/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | MAY BE ADDED 28 FEB 25 1. Shot pins are missing in interiors walls, within 6" of every edge. 2. Truss A1E is missing lateral bracing, just south of first brace. |
|
| 03/03/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 3 MAR 25 ALL CORRECTIONS HAVE BEEN MADE. |