Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Address:
2381 S CLOVIS PL
Apply Date:
01/25/2024
Applicant:
Description:
SFR PANT2022 T22-M0073 Pantano Vista Lots 1-32

Permit Reviews

Permit Number - TC-MDP-0124-00065
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073 Pantano Vista Lots 1-32
Start Date Submittal Complete Date Status  
01/26/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 01/30/2024 REQUIRES RESUBMIT Review Details
01/31/2024 SITE FROM MODEL PERMIT - PRODUCTION v.2 02/01/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0124-00065
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073 Pantano Vista Lots 1-32
Total Outstanding Activity Conditions - 3
Date Name
01/10/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
06/15/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
12/12/2022 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Conditions

Permit Number - TC-MDP-0124-00065
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073 Pantano Vista Lots 1-32
Date Description Comments
01/10/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
06/15/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
01/26/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0124-00065
Permit Description: SFR PANT2022 T22-M0073 Pantano Vista Lots 1-32
Total Completed Inspections - 13
Date Description Inspector Results Comments
03/14/2024 COT - RSPL - Backwater Valve Passed
03/14/2024 COT - RSPL - Rough Soil Passed
03/14/2024 COT - RSPL - Sewer Passed
03/14/2024 COT - RSPL - Yard Water Line Passed
03/22/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
03/22/2024 COT - RSBU - Preslab Passed
03/22/2024 COT - RSEL - Grounding/Bonding Passed
05/01/2024 COT - RSBU - Exterior Clips/Sheathing Passed All exterior walls are sheathed with plywood and are nailed per plans. Interior shear walls are properly installed and are nailed per plans. Bottom plates are held down by bolts, shot pins, or cut nails. All shear clips and masa clips are properly nailed to walls and bottom plates. Okay to proceed with dry-in for stucco applications.
05/01/2024 COT - RSBU - Roof Nailing Passed Trusses are nailed to top plate and have H2.5 clips attached. Plywood sheathing is properly nailed to trusses per plan and code. Okay to proceed with top out of plumbing.
05/15/2024 COT - RSEL - Electrical Underground Passed
05/17/2024 BULD - Electrical Clearance Passed ECO Clearance issued.
07/02/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
07/15/2024 COT - RSBU - Interior Shear Bracing Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
SITE PLAN LOT 31_V1_V2.PDF DOCUMENTS VIEW